病人监测SpO2和体温参数

Moch Sahrul Triandi Putra Sahrul, Triwiyanto Triwiyanto, Torib Hamzah
{"title":"病人监测SpO2和体温参数","authors":"Moch Sahrul Triandi Putra Sahrul, Triwiyanto Triwiyanto, Torib Hamzah","doi":"10.35882/JEEEMI.V1I2.2","DOIUrl":null,"url":null,"abstract":"Patient monitor is an apparatus used to monitor the patient's condition in real-time, hence the patient's physiological conditions can be identified at that time. The purpose of this study is to design a patient monitor for SpO2 and temperature parameters based on computer with Delphi progaming. In this work, the author developed  patient monitor with two parameters (SpO2 and Temperature). The workings of this tool are very simple by installing the finger sensor on the finger and the temperature sensor in the armpit area will then be detected by the two sensors that will be displayed on the PC and LCD Characters, analog data from the ADC Atmega is received by the personal computer (PC) via Bluetooth HC -05 and values ​​per parameter are also displayed on the Character LCD. After measuring, get an error in the tool, the biggest SpO2 error of this tool is 1.02% and get the smallest error of 0.8%. And for the biggest error of Temperature of 1.02% and the smallest error of 0.8%.","PeriodicalId":369032,"journal":{"name":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Patient Monitor for SpO2 and Temperature Parameters\",\"authors\":\"Moch Sahrul Triandi Putra Sahrul, Triwiyanto Triwiyanto, Torib Hamzah\",\"doi\":\"10.35882/JEEEMI.V1I2.2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Patient monitor is an apparatus used to monitor the patient's condition in real-time, hence the patient's physiological conditions can be identified at that time. The purpose of this study is to design a patient monitor for SpO2 and temperature parameters based on computer with Delphi progaming. In this work, the author developed  patient monitor with two parameters (SpO2 and Temperature). The workings of this tool are very simple by installing the finger sensor on the finger and the temperature sensor in the armpit area will then be detected by the two sensors that will be displayed on the PC and LCD Characters, analog data from the ADC Atmega is received by the personal computer (PC) via Bluetooth HC -05 and values ​​per parameter are also displayed on the Character LCD. After measuring, get an error in the tool, the biggest SpO2 error of this tool is 1.02% and get the smallest error of 0.8%. And for the biggest error of Temperature of 1.02% and the smallest error of 0.8%.\",\"PeriodicalId\":369032,\"journal\":{\"name\":\"Journal of Electronics, Electromedical Engineering, and Medical Informatics\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electronics, Electromedical Engineering, and Medical Informatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35882/JEEEMI.V1I2.2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35882/JEEEMI.V1I2.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

患者监护仪是一种用于实时监测患者病情的仪器,因此可以在当时识别患者的生理状况。本研究的目的是利用Delphi程序设计一种基于计算机的SpO2和体温参数监护仪。在这项工作中,作者开发了两个参数(SpO2和温度)的患者监护仪。该工具的工作非常简单,只需将手指传感器安装在手指上,腋窝区域的温度传感器将由两个传感器检测,这些传感器将显示在PC和LCD字符上,来自ADC Atmega的模拟数据由个人计算机(PC)通过蓝牙HC -05接收,每个参数的值也显示在字符LCD上。测量后,在刀具中得到误差,该刀具的最大SpO2误差为1.02%,最小误差为0.8%。温度的最大误差为1.02%,最小误差为0.8%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Patient Monitor for SpO2 and Temperature Parameters
Patient monitor is an apparatus used to monitor the patient's condition in real-time, hence the patient's physiological conditions can be identified at that time. The purpose of this study is to design a patient monitor for SpO2 and temperature parameters based on computer with Delphi progaming. In this work, the author developed  patient monitor with two parameters (SpO2 and Temperature). The workings of this tool are very simple by installing the finger sensor on the finger and the temperature sensor in the armpit area will then be detected by the two sensors that will be displayed on the PC and LCD Characters, analog data from the ADC Atmega is received by the personal computer (PC) via Bluetooth HC -05 and values ​​per parameter are also displayed on the Character LCD. After measuring, get an error in the tool, the biggest SpO2 error of this tool is 1.02% and get the smallest error of 0.8%. And for the biggest error of Temperature of 1.02% and the smallest error of 0.8%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信