vsc - hvdc连接海上风电场故障特征及距离保护适应性分析

F. Peng, Houlei Gao, Weiying Miao, Xinchi Feng, Bin Xu, Yitong Wu
{"title":"vsc - hvdc连接海上风电场故障特征及距离保护适应性分析","authors":"F. Peng, Houlei Gao, Weiying Miao, Xinchi Feng, Bin Xu, Yitong Wu","doi":"10.1109/AEEES56888.2023.10114234","DOIUrl":null,"url":null,"abstract":"With the characteristics of low loss, low harmonic content and large transmission capacity, voltage source converter based high voltage direct current transmission (VSC-HVDC) has become the focus of the development for large-capacity and long-distance power transmission system connected with offshore wind farms. However, since the power supplies on both sides are controlled, the fault characteristics are changed, and the performance of the traditional distance protection is influenced. Based on the control strategy, the amplitude and phase angle of the equivalent positive and negative sequence impedances at the two sides of the transmission line are analyzed, and the current phasor expressions of the wind farm side and the VSC-HVDC side of the faulted line are derived. Then the adaptability of distance protection using power frequency component (DPPFC) of transmission line for VSC-HVDC-connected offshore wind farm is analyzed under different fault conditions. The results show that the amplitude and phase angle of the equivalent positive and negative sequence impedances of the wind farm and the VSC-HVDC system are affected by the control strategy of the converter and the fault conditions. The DPPFC is not suitable for VSC-HVDC-connected offshore wind farm system. The ability to avoid the effect of fault resistance of the DPPFC at the wind farm side gets worse. The simulation conducted by EMTP-RV verifies the effectiveness of the analysis.","PeriodicalId":272114,"journal":{"name":"2023 5th Asia Energy and Electrical Engineering Symposium (AEEES)","volume":"103 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of Fault Characteristics and Distance Protection Adaptability for VSC-HVDC-Connected Offshore Wind Farms\",\"authors\":\"F. Peng, Houlei Gao, Weiying Miao, Xinchi Feng, Bin Xu, Yitong Wu\",\"doi\":\"10.1109/AEEES56888.2023.10114234\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the characteristics of low loss, low harmonic content and large transmission capacity, voltage source converter based high voltage direct current transmission (VSC-HVDC) has become the focus of the development for large-capacity and long-distance power transmission system connected with offshore wind farms. However, since the power supplies on both sides are controlled, the fault characteristics are changed, and the performance of the traditional distance protection is influenced. Based on the control strategy, the amplitude and phase angle of the equivalent positive and negative sequence impedances at the two sides of the transmission line are analyzed, and the current phasor expressions of the wind farm side and the VSC-HVDC side of the faulted line are derived. Then the adaptability of distance protection using power frequency component (DPPFC) of transmission line for VSC-HVDC-connected offshore wind farm is analyzed under different fault conditions. The results show that the amplitude and phase angle of the equivalent positive and negative sequence impedances of the wind farm and the VSC-HVDC system are affected by the control strategy of the converter and the fault conditions. The DPPFC is not suitable for VSC-HVDC-connected offshore wind farm system. The ability to avoid the effect of fault resistance of the DPPFC at the wind farm side gets worse. The simulation conducted by EMTP-RV verifies the effectiveness of the analysis.\",\"PeriodicalId\":272114,\"journal\":{\"name\":\"2023 5th Asia Energy and Electrical Engineering Symposium (AEEES)\",\"volume\":\"103 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 5th Asia Energy and Electrical Engineering Symposium (AEEES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEEES56888.2023.10114234\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 5th Asia Energy and Electrical Engineering Symposium (AEEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEEES56888.2023.10114234","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

基于电压源变流器的高压直流输电系统(VSC-HVDC)具有低损耗、低谐波含量和大传输容量的特点,已成为与海上风电场连接的大容量远距离输电系统的发展重点。但由于两侧电源受到控制,改变了故障特征,影响了传统距离保护的性能。基于该控制策略,分析了输电线路两侧等效正负序阻抗的幅值和相角,推导出了故障线路风电场侧和直流直流侧的电流相量表达式。在此基础上,分析了输电线路工频分量(DPPFC)对不同故障条件下海上风电场距离保护的适应性。结果表明,变流器控制策略和故障条件对风电场和直流-直流系统等效正负序阻抗的幅值和相位角均有影响。DPPFC不适合于vdc - hvdc连接的海上风电场系统。风电场侧DPPFC规避故障抗力影响的能力变差。EMTP-RV仿真验证了分析的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of Fault Characteristics and Distance Protection Adaptability for VSC-HVDC-Connected Offshore Wind Farms
With the characteristics of low loss, low harmonic content and large transmission capacity, voltage source converter based high voltage direct current transmission (VSC-HVDC) has become the focus of the development for large-capacity and long-distance power transmission system connected with offshore wind farms. However, since the power supplies on both sides are controlled, the fault characteristics are changed, and the performance of the traditional distance protection is influenced. Based on the control strategy, the amplitude and phase angle of the equivalent positive and negative sequence impedances at the two sides of the transmission line are analyzed, and the current phasor expressions of the wind farm side and the VSC-HVDC side of the faulted line are derived. Then the adaptability of distance protection using power frequency component (DPPFC) of transmission line for VSC-HVDC-connected offshore wind farm is analyzed under different fault conditions. The results show that the amplitude and phase angle of the equivalent positive and negative sequence impedances of the wind farm and the VSC-HVDC system are affected by the control strategy of the converter and the fault conditions. The DPPFC is not suitable for VSC-HVDC-connected offshore wind farm system. The ability to avoid the effect of fault resistance of the DPPFC at the wind farm side gets worse. The simulation conducted by EMTP-RV verifies the effectiveness of the analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信