Xitong Xu, Zhengsen Jia, Lei Wang, Tiandi Zhou, Jiangtao Zhang, Xianlin Pan, Zhaomin Shi
{"title":"基于交流量子电压的谐波电压测量精度研究","authors":"Xitong Xu, Zhengsen Jia, Lei Wang, Tiandi Zhou, Jiangtao Zhang, Xianlin Pan, Zhaomin Shi","doi":"10.1109/CPEM49742.2020.9191758","DOIUrl":null,"url":null,"abstract":"In this paper, factors affecting harmonic measurement accuracy were analyzed, which is based on AC quantum voltage. Two factors, the non-integer period sampling and the number of steps, that influence the harmonic measurement are identified. The sensitivity of each influential factor is verified by experiments. In our system the sampling complement is under 0.005 and the non-integer periodic error is less than 10−7. The number of steps should be more than two times of the highest harmonics contained in the signal in order to avoid signal aliasing.","PeriodicalId":373216,"journal":{"name":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","volume":"426 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on Harmonic Voltage Measurement Accuracy Based on AC Quantum Voltage\",\"authors\":\"Xitong Xu, Zhengsen Jia, Lei Wang, Tiandi Zhou, Jiangtao Zhang, Xianlin Pan, Zhaomin Shi\",\"doi\":\"10.1109/CPEM49742.2020.9191758\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, factors affecting harmonic measurement accuracy were analyzed, which is based on AC quantum voltage. Two factors, the non-integer period sampling and the number of steps, that influence the harmonic measurement are identified. The sensitivity of each influential factor is verified by experiments. In our system the sampling complement is under 0.005 and the non-integer periodic error is less than 10−7. The number of steps should be more than two times of the highest harmonics contained in the signal in order to avoid signal aliasing.\",\"PeriodicalId\":373216,\"journal\":{\"name\":\"2020 Conference on Precision Electromagnetic Measurements (CPEM)\",\"volume\":\"426 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 Conference on Precision Electromagnetic Measurements (CPEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM49742.2020.9191758\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM49742.2020.9191758","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on Harmonic Voltage Measurement Accuracy Based on AC Quantum Voltage
In this paper, factors affecting harmonic measurement accuracy were analyzed, which is based on AC quantum voltage. Two factors, the non-integer period sampling and the number of steps, that influence the harmonic measurement are identified. The sensitivity of each influential factor is verified by experiments. In our system the sampling complement is under 0.005 and the non-integer periodic error is less than 10−7. The number of steps should be more than two times of the highest harmonics contained in the signal in order to avoid signal aliasing.