头戴显示器对单腿站立稳定性的分析

B. Woo
{"title":"头戴显示器对单腿站立稳定性的分析","authors":"B. Woo","doi":"10.5103/KJSB.2017.27.2.149","DOIUrl":null,"url":null,"abstract":"Objective: The purpose of this study was to investigate the effects of three visual conditions (eyes opened, eyes closed, and wearing of a head mounted display [HMD]) on single-leg standing through kinematics and kinetic analysis. Method: Twelve college students (age: 24.5 ± 2.6 years, height: 175.0 ± 6.4 cm, weight: 69.2 ± 5.1 kg) participated in this study. The study method adopted three-dimensional analysis with six cameras and ground reaction force measurement with one force plate. The analysis variables were coefficient of variation (CV) of the center of body mass, head movement, ground reaction force, and center of pressure, which were analyzed using one-way analysis of variance with repeated measures according to visual conditions. Results: In most cases, the results of this study showed that the CV was significantly higher in the order of HMD wearing, eyes closed, and eyes opened conditions. Conclusion: Our results indicated that body sway was the largest in the HMD wearing condition, and the risk of falling was high owing to the low stability.","PeriodicalId":306685,"journal":{"name":"Korean Journal of Sport Biomechanics","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of Stability on Single-leg Standing by Wearing a Head Mounted Display\",\"authors\":\"B. Woo\",\"doi\":\"10.5103/KJSB.2017.27.2.149\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: The purpose of this study was to investigate the effects of three visual conditions (eyes opened, eyes closed, and wearing of a head mounted display [HMD]) on single-leg standing through kinematics and kinetic analysis. Method: Twelve college students (age: 24.5 ± 2.6 years, height: 175.0 ± 6.4 cm, weight: 69.2 ± 5.1 kg) participated in this study. The study method adopted three-dimensional analysis with six cameras and ground reaction force measurement with one force plate. The analysis variables were coefficient of variation (CV) of the center of body mass, head movement, ground reaction force, and center of pressure, which were analyzed using one-way analysis of variance with repeated measures according to visual conditions. Results: In most cases, the results of this study showed that the CV was significantly higher in the order of HMD wearing, eyes closed, and eyes opened conditions. Conclusion: Our results indicated that body sway was the largest in the HMD wearing condition, and the risk of falling was high owing to the low stability.\",\"PeriodicalId\":306685,\"journal\":{\"name\":\"Korean Journal of Sport Biomechanics\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Sport Biomechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5103/KJSB.2017.27.2.149\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Sport Biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5103/KJSB.2017.27.2.149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

目的:通过运动学和动力学分析,探讨三种视觉条件(睁眼、闭眼和佩戴头戴式显示器[HMD])对单腿站立的影响。方法:12名大学生(年龄:24.5±2.6岁,身高:175.0±6.4 cm,体重:69.2±5.1 kg)参与研究。研究方法采用6台摄像机的三维分析和1个测力板的地面反力测量。分析变量为身体质量中心、头部运动、地面反作用力和压力中心的变异系数(CV),根据视觉条件采用重复测量的单向方差分析。结果:在大多数情况下,本研究的结果显示,CV在佩戴HMD、闭眼和睁眼的情况下显著较高。结论:我们的研究结果表明,在佩戴HMD时,身体摆动最大,由于稳定性低,跌倒的风险高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of Stability on Single-leg Standing by Wearing a Head Mounted Display
Objective: The purpose of this study was to investigate the effects of three visual conditions (eyes opened, eyes closed, and wearing of a head mounted display [HMD]) on single-leg standing through kinematics and kinetic analysis. Method: Twelve college students (age: 24.5 ± 2.6 years, height: 175.0 ± 6.4 cm, weight: 69.2 ± 5.1 kg) participated in this study. The study method adopted three-dimensional analysis with six cameras and ground reaction force measurement with one force plate. The analysis variables were coefficient of variation (CV) of the center of body mass, head movement, ground reaction force, and center of pressure, which were analyzed using one-way analysis of variance with repeated measures according to visual conditions. Results: In most cases, the results of this study showed that the CV was significantly higher in the order of HMD wearing, eyes closed, and eyes opened conditions. Conclusion: Our results indicated that body sway was the largest in the HMD wearing condition, and the risk of falling was high owing to the low stability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信