用户对身披360°摄像机位置和高度的感知分析

Kevin P. Pfeil, P. Wisniewski, J. Laviola
{"title":"用户对身披360°摄像机位置和高度的感知分析","authors":"Kevin P. Pfeil, P. Wisniewski, J. Laviola","doi":"10.1145/3343036.3343120","DOIUrl":null,"url":null,"abstract":"Our work investigates body-worn 360° camera placements for telepresence, to balance height and clarity of view. We conducted a user study in a Virtual Reality (VR) simulation, using a 3x3 within-subjects experimental design varying placement and height, with 26 participants. We found that shoulder mounted cameras were significantly less preferable than our other conditions due to the occlusions caused by the wearer’s head. Our results did not show a significant effect of camera height within a range of +/- 12 inches from the user’s natural height. As such, in the context of body-worn 360° cameras, there is leeway for camera height, whereas strategic bodily placements are more important. Based on these results, we provide design recommendations for content creators using wearable cameras for immersive telepresence.","PeriodicalId":228010,"journal":{"name":"ACM Symposium on Applied Perception 2019","volume":"140 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"An Analysis of User Perception Regarding Body-Worn 360° Camera Placements and Heights for Telepresence\",\"authors\":\"Kevin P. Pfeil, P. Wisniewski, J. Laviola\",\"doi\":\"10.1145/3343036.3343120\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Our work investigates body-worn 360° camera placements for telepresence, to balance height and clarity of view. We conducted a user study in a Virtual Reality (VR) simulation, using a 3x3 within-subjects experimental design varying placement and height, with 26 participants. We found that shoulder mounted cameras were significantly less preferable than our other conditions due to the occlusions caused by the wearer’s head. Our results did not show a significant effect of camera height within a range of +/- 12 inches from the user’s natural height. As such, in the context of body-worn 360° cameras, there is leeway for camera height, whereas strategic bodily placements are more important. Based on these results, we provide design recommendations for content creators using wearable cameras for immersive telepresence.\",\"PeriodicalId\":228010,\"journal\":{\"name\":\"ACM Symposium on Applied Perception 2019\",\"volume\":\"140 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACM Symposium on Applied Perception 2019\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3343036.3343120\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACM Symposium on Applied Perception 2019","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3343036.3343120","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

我们的工作是研究远程呈现的360°摄像机位置,以平衡高度和清晰的视角。我们在虚拟现实(VR)模拟中进行了一项用户研究,使用3 × 3的受试者内实验设计,不同的位置和高度,有26名参与者。我们发现,由于佩戴者头部造成的闭塞,肩部安装的摄像头明显不如其他情况更可取。我们的结果没有显示出相机高度在用户自然高度+/- 12英寸范围内的显著影响。因此,在人体佩戴的360°相机的背景下,相机高度有余地,而战略性的身体位置更重要。基于这些结果,我们为使用可穿戴相机进行沉浸式远程呈现的内容创作者提供了设计建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Analysis of User Perception Regarding Body-Worn 360° Camera Placements and Heights for Telepresence
Our work investigates body-worn 360° camera placements for telepresence, to balance height and clarity of view. We conducted a user study in a Virtual Reality (VR) simulation, using a 3x3 within-subjects experimental design varying placement and height, with 26 participants. We found that shoulder mounted cameras were significantly less preferable than our other conditions due to the occlusions caused by the wearer’s head. Our results did not show a significant effect of camera height within a range of +/- 12 inches from the user’s natural height. As such, in the context of body-worn 360° cameras, there is leeway for camera height, whereas strategic bodily placements are more important. Based on these results, we provide design recommendations for content creators using wearable cameras for immersive telepresence.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信