使用三维打印的患者专用钻孔导轨在脊柱畸形犬胸腰椎置入椎弓根螺钉的准确性

James Elford, B. Oxley, S. Behr
{"title":"使用三维打印的患者专用钻孔导轨在脊柱畸形犬胸腰椎置入椎弓根螺钉的准确性","authors":"James Elford, B. Oxley, S. Behr","doi":"10.1111/vsu.13333","DOIUrl":null,"url":null,"abstract":"OBJECTIVE\nTo determine the accuracy of pedicle screw placement in the thoracic spine of dogs with spinal deformities with three-dimensionally (3D) printed patient-specific drill guides.\n\n\nSTUDY DESIGN\nRetrospective study.\n\n\nSAMPLE POPULATION\nSix dogs in which sixty pedicle screws were placed in the thoracolumbar spine.\n\n\nMETHODS\nMedical records were searched between June 2017 and June 2018 for dogs with clinical signs associated with a thoracolumbar vertebral malformation. Inclusion criteria included MRI and computed tomography (CT) data that were used to create 3D printed patient-specific drill guides. All dogs were stabilized dorsally with guided bicortical pedicle screws and polymethylmethacrylate. Accuracy of screw placement was assessed by immediately postoperative CT according to a modified Zdichavsky classification.\n\n\nRESULTS\nFive pugs and one French bulldog met the inclusion criteria. Sixty bicortical pedicle screws were placed; 96.7% were graded as I (optimal placement), and 3.3% were classified as IIa (partial penetration of the medial pedicle wall) according to a modified Zdichavsky classification.\n\n\nCONCLUSION\nThree-dimensionally printed patient-specific drill guides allowed safe and accurate placement of pedicle screws in the thoracolumbar spine in dogs with vertebral malformation.\n\n\nCLINICAL SIGNIFICANCE\nThree-dimensionally printed patient-specific drill guides are a safe and effective method of placing pedicle screws in dogs with thoracolumbar vertebral malformations.","PeriodicalId":123280,"journal":{"name":"Veterinary surgery : VS","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Accuracy of placement of pedicle screws in the thoracolumbar spine of dogs with spinal deformities with three-dimensionally printed patient-specific drill guides.\",\"authors\":\"James Elford, B. Oxley, S. Behr\",\"doi\":\"10.1111/vsu.13333\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVE\\nTo determine the accuracy of pedicle screw placement in the thoracic spine of dogs with spinal deformities with three-dimensionally (3D) printed patient-specific drill guides.\\n\\n\\nSTUDY DESIGN\\nRetrospective study.\\n\\n\\nSAMPLE POPULATION\\nSix dogs in which sixty pedicle screws were placed in the thoracolumbar spine.\\n\\n\\nMETHODS\\nMedical records were searched between June 2017 and June 2018 for dogs with clinical signs associated with a thoracolumbar vertebral malformation. Inclusion criteria included MRI and computed tomography (CT) data that were used to create 3D printed patient-specific drill guides. All dogs were stabilized dorsally with guided bicortical pedicle screws and polymethylmethacrylate. Accuracy of screw placement was assessed by immediately postoperative CT according to a modified Zdichavsky classification.\\n\\n\\nRESULTS\\nFive pugs and one French bulldog met the inclusion criteria. Sixty bicortical pedicle screws were placed; 96.7% were graded as I (optimal placement), and 3.3% were classified as IIa (partial penetration of the medial pedicle wall) according to a modified Zdichavsky classification.\\n\\n\\nCONCLUSION\\nThree-dimensionally printed patient-specific drill guides allowed safe and accurate placement of pedicle screws in the thoracolumbar spine in dogs with vertebral malformation.\\n\\n\\nCLINICAL SIGNIFICANCE\\nThree-dimensionally printed patient-specific drill guides are a safe and effective method of placing pedicle screws in dogs with thoracolumbar vertebral malformations.\",\"PeriodicalId\":123280,\"journal\":{\"name\":\"Veterinary surgery : VS\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary surgery : VS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1111/vsu.13333\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary surgery : VS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/vsu.13333","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

摘要

目的利用3D打印的患者专用钻头,确定犬胸椎椎弓根螺钉在脊柱畸形犬胸椎置入的准确性。研究设计回顾性研究。6只狗,其中60枚椎弓根螺钉放置在胸腰椎。方法检索2017年6月至2018年6月期间与胸腰椎畸形相关临床症状的犬的医疗记录。纳入标准包括MRI和计算机断层扫描(CT)数据,用于创建3D打印的患者特定钻头指南。所有犬均采用双皮质椎弓根螺钉和聚甲基丙烯酸甲酯进行背侧稳定。根据改良的Zdichavsky分类,术后立即通过CT评估螺钉放置的准确性。结果5只哈巴狗和1只法国斗牛犬符合入选标准。放置60枚双皮质椎弓根螺钉;96.7%为I级(最佳放置),3.3%为IIa级(部分穿透内侧蒂管壁)(根据改良的Zdichavsky分类)。结论三维打印的患者专用钻头可安全、准确地将椎弓根螺钉置入犬椎体畸形胸腰椎。临床意义:三维打印的患者专用钻头是胸腰椎畸形犬椎弓根螺钉放置的一种安全有效的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of placement of pedicle screws in the thoracolumbar spine of dogs with spinal deformities with three-dimensionally printed patient-specific drill guides.
OBJECTIVE To determine the accuracy of pedicle screw placement in the thoracic spine of dogs with spinal deformities with three-dimensionally (3D) printed patient-specific drill guides. STUDY DESIGN Retrospective study. SAMPLE POPULATION Six dogs in which sixty pedicle screws were placed in the thoracolumbar spine. METHODS Medical records were searched between June 2017 and June 2018 for dogs with clinical signs associated with a thoracolumbar vertebral malformation. Inclusion criteria included MRI and computed tomography (CT) data that were used to create 3D printed patient-specific drill guides. All dogs were stabilized dorsally with guided bicortical pedicle screws and polymethylmethacrylate. Accuracy of screw placement was assessed by immediately postoperative CT according to a modified Zdichavsky classification. RESULTS Five pugs and one French bulldog met the inclusion criteria. Sixty bicortical pedicle screws were placed; 96.7% were graded as I (optimal placement), and 3.3% were classified as IIa (partial penetration of the medial pedicle wall) according to a modified Zdichavsky classification. CONCLUSION Three-dimensionally printed patient-specific drill guides allowed safe and accurate placement of pedicle screws in the thoracolumbar spine in dogs with vertebral malformation. CLINICAL SIGNIFICANCE Three-dimensionally printed patient-specific drill guides are a safe and effective method of placing pedicle screws in dogs with thoracolumbar vertebral malformations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信