实验用kegagalan突破化学锚钉法浇筑到位丹柱安装登甘改性卡司鲁邦钻头提取器

Novera Kresiariati, H. Apriyatno
{"title":"实验用kegagalan突破化学锚钉法浇筑到位丹柱安装登甘改性卡司鲁邦钻头提取器","authors":"Novera Kresiariati, H. Apriyatno","doi":"10.53866/jimi.v2i3.104","DOIUrl":null,"url":null,"abstract":"Anchors are needed to transmit the load to the concrete in strengthening the structure of a building. The anchor is installed in two ways, namely the cast in place method and the post installed method. In the post installed method, given Sika anchorfix-2 adhesive. The study was conducted to determine the type of failure that occurred, the pullout capacity of the anchor implanted on the hef 90 mm, and the average value of the adhesive strength (μ) of the M12 x 160 mm stud anchor on the T beam specimen measuring 390 x 270 x 300 mm as many as three samples. Each method of cast in place, post installed plain holes, and post installed screw holes using 32.30 MPa fc' concrete with pullout test. The results of the study, the type of failure that occurs is a breakout failure. The pulling capacity value obtained in the cast in place method is 14415.78 N, the plain hole post installed method is 77603.29 N, and the screw hole post installed method is 87377.25 N. The anchoring strength capacity of the plain hole post installed method is higher. greater than the cast in place method with an increase of 6.82%, the adhesive strength of the post installed method with threaded holes is greater than the cast in place method with an increase of 8.14%, and the adhesive strength of the post installed method of threaded holes is greater than the post installed method of holes plain with an increase of 1.24%.","PeriodicalId":414894,"journal":{"name":"Citizen : Jurnal Ilmiah Multidisiplin Indonesia","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"EKSPERIMEN KEGAGALAN BREAKOUT CHEMICAL ANCHOR STUD METODE CAST IN PLACE DAN POST INSTALLED DENGAN MODIFIKASI LUBANG DRILL BIT EXTRACTOR\",\"authors\":\"Novera Kresiariati, H. Apriyatno\",\"doi\":\"10.53866/jimi.v2i3.104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Anchors are needed to transmit the load to the concrete in strengthening the structure of a building. The anchor is installed in two ways, namely the cast in place method and the post installed method. In the post installed method, given Sika anchorfix-2 adhesive. The study was conducted to determine the type of failure that occurred, the pullout capacity of the anchor implanted on the hef 90 mm, and the average value of the adhesive strength (μ) of the M12 x 160 mm stud anchor on the T beam specimen measuring 390 x 270 x 300 mm as many as three samples. Each method of cast in place, post installed plain holes, and post installed screw holes using 32.30 MPa fc' concrete with pullout test. The results of the study, the type of failure that occurs is a breakout failure. The pulling capacity value obtained in the cast in place method is 14415.78 N, the plain hole post installed method is 77603.29 N, and the screw hole post installed method is 87377.25 N. The anchoring strength capacity of the plain hole post installed method is higher. greater than the cast in place method with an increase of 6.82%, the adhesive strength of the post installed method with threaded holes is greater than the cast in place method with an increase of 8.14%, and the adhesive strength of the post installed method of threaded holes is greater than the post installed method of holes plain with an increase of 1.24%.\",\"PeriodicalId\":414894,\"journal\":{\"name\":\"Citizen : Jurnal Ilmiah Multidisiplin Indonesia\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Citizen : Jurnal Ilmiah Multidisiplin Indonesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53866/jimi.v2i3.104\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Citizen : Jurnal Ilmiah Multidisiplin Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53866/jimi.v2i3.104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在加固建筑物结构时,需要用锚杆将荷载传递给混凝土。锚杆安装有两种方式,即就地浇筑法和立柱安装法。在柱式安装方法中,给予西卡anchor -2胶粘剂。研究确定了发生破坏的类型,锚植入高度为90mm的锚杆的拔出能力,以及M12 × 160mm螺柱锚在390 × 270 × 300mm的T梁试件上多达3个试件的粘接强度(μ)的平均值。每一种方法均采用就地浇筑、柱装平孔、柱装螺孔,采用32.30 MPa fc混凝土进行拉拔试验。研究结果表明,发生的故障类型是突发性故障。现浇法获得的拉拔能力值为14415.78 N,平孔桩安装法获得的拉拔能力值为77603.29 N,螺孔桩安装法获得的拉拔能力值为87377.25 N,平孔桩安装法获得的锚固强度能力更高。比现浇法增大6.82%,带螺纹孔的桩装法的粘接强度比现浇法增大8.14%,带螺纹孔的桩装法的粘接强度比无孔的桩装法增大1.24%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
EKSPERIMEN KEGAGALAN BREAKOUT CHEMICAL ANCHOR STUD METODE CAST IN PLACE DAN POST INSTALLED DENGAN MODIFIKASI LUBANG DRILL BIT EXTRACTOR
Anchors are needed to transmit the load to the concrete in strengthening the structure of a building. The anchor is installed in two ways, namely the cast in place method and the post installed method. In the post installed method, given Sika anchorfix-2 adhesive. The study was conducted to determine the type of failure that occurred, the pullout capacity of the anchor implanted on the hef 90 mm, and the average value of the adhesive strength (μ) of the M12 x 160 mm stud anchor on the T beam specimen measuring 390 x 270 x 300 mm as many as three samples. Each method of cast in place, post installed plain holes, and post installed screw holes using 32.30 MPa fc' concrete with pullout test. The results of the study, the type of failure that occurs is a breakout failure. The pulling capacity value obtained in the cast in place method is 14415.78 N, the plain hole post installed method is 77603.29 N, and the screw hole post installed method is 87377.25 N. The anchoring strength capacity of the plain hole post installed method is higher. greater than the cast in place method with an increase of 6.82%, the adhesive strength of the post installed method with threaded holes is greater than the cast in place method with an increase of 8.14%, and the adhesive strength of the post installed method of threaded holes is greater than the post installed method of holes plain with an increase of 1.24%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信