{"title":"一种野外便携式细菌生物发光毒性测试仪","authors":"Min-Chol Shin, Jeong-Gun Lee, K. Yun, J. Park","doi":"10.1109/ICSENS.2007.355737","DOIUrl":null,"url":null,"abstract":"This paper describes a simple, inexpensive and easily constructed toxicity biosensor that uses freeze-dried bioluminescent bacteria, photobacterium phosphoreum IFO 13896. To compensate for bacterial activity, we apply a differential photometer circuit to measure bioluminescence. Instead of a photomultiplier tube, dual photodiodes were used to reduce the cost of the sensor system. The concentrations of toxic compounds causing 50% light loss (50% effective concentrations, EC50) were determined immediately and 30 min after rehydration of the bacteria from a freeze-dried state. The EC50 values at dual mode operation with differential amplification are nearly constant for the temperature range between 10 and 25degC, whereas the EC50 values at single mode operation increase with temperature, resulting in low sensitivity. The performance of the portable biosensor as a tool for determining p-nitrophenol, mercury, cadmium, and lead toxicity is demonstrated.","PeriodicalId":233838,"journal":{"name":"2006 5th IEEE Conference on Sensors","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Field-Portable Toxicity Tester using Bacterial Bioluminescence\",\"authors\":\"Min-Chol Shin, Jeong-Gun Lee, K. Yun, J. Park\",\"doi\":\"10.1109/ICSENS.2007.355737\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a simple, inexpensive and easily constructed toxicity biosensor that uses freeze-dried bioluminescent bacteria, photobacterium phosphoreum IFO 13896. To compensate for bacterial activity, we apply a differential photometer circuit to measure bioluminescence. Instead of a photomultiplier tube, dual photodiodes were used to reduce the cost of the sensor system. The concentrations of toxic compounds causing 50% light loss (50% effective concentrations, EC50) were determined immediately and 30 min after rehydration of the bacteria from a freeze-dried state. The EC50 values at dual mode operation with differential amplification are nearly constant for the temperature range between 10 and 25degC, whereas the EC50 values at single mode operation increase with temperature, resulting in low sensitivity. The performance of the portable biosensor as a tool for determining p-nitrophenol, mercury, cadmium, and lead toxicity is demonstrated.\",\"PeriodicalId\":233838,\"journal\":{\"name\":\"2006 5th IEEE Conference on Sensors\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 5th IEEE Conference on Sensors\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2007.355737\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 5th IEEE Conference on Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2007.355737","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Field-Portable Toxicity Tester using Bacterial Bioluminescence
This paper describes a simple, inexpensive and easily constructed toxicity biosensor that uses freeze-dried bioluminescent bacteria, photobacterium phosphoreum IFO 13896. To compensate for bacterial activity, we apply a differential photometer circuit to measure bioluminescence. Instead of a photomultiplier tube, dual photodiodes were used to reduce the cost of the sensor system. The concentrations of toxic compounds causing 50% light loss (50% effective concentrations, EC50) were determined immediately and 30 min after rehydration of the bacteria from a freeze-dried state. The EC50 values at dual mode operation with differential amplification are nearly constant for the temperature range between 10 and 25degC, whereas the EC50 values at single mode operation increase with temperature, resulting in low sensitivity. The performance of the portable biosensor as a tool for determining p-nitrophenol, mercury, cadmium, and lead toxicity is demonstrated.