非理想电网条件下三相对称锁相环特性分析

Tianyi Su, Hua Lin, Shaojie Li, Xingwei Wang
{"title":"非理想电网条件下三相对称锁相环特性分析","authors":"Tianyi Su, Hua Lin, Shaojie Li, Xingwei Wang","doi":"10.1109/ICPST56889.2023.10165059","DOIUrl":null,"url":null,"abstract":"Under weak grids, the output impedance of grid-connected inverter is coupled with the grid impedance, leading to poor quality of the grid current. To address this issue, the symmetrical phase-locked loop (PLL) has been proposed which can eliminate the frequency coupling and attribute the system model to be symmetrical. Although the system performances well under steady state, the characteristics of the inverter is unclear under non-ideal conditions at present. In this article, by investigating the inverter performance with the symmetrical PLL under different grid conditions, it is founded that both the dynamic and steady-state characteristics become worse compared to that with synchronous reference frame (SRF) PLL. The experiments validate the correctness of the theoretical analysis.","PeriodicalId":231392,"journal":{"name":"2023 IEEE International Conference on Power Science and Technology (ICPST)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characteristics Analysis of Three-Phase Symmetrical Phase-Locked Loop under Non-Ideal Grid Conditions\",\"authors\":\"Tianyi Su, Hua Lin, Shaojie Li, Xingwei Wang\",\"doi\":\"10.1109/ICPST56889.2023.10165059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Under weak grids, the output impedance of grid-connected inverter is coupled with the grid impedance, leading to poor quality of the grid current. To address this issue, the symmetrical phase-locked loop (PLL) has been proposed which can eliminate the frequency coupling and attribute the system model to be symmetrical. Although the system performances well under steady state, the characteristics of the inverter is unclear under non-ideal conditions at present. In this article, by investigating the inverter performance with the symmetrical PLL under different grid conditions, it is founded that both the dynamic and steady-state characteristics become worse compared to that with synchronous reference frame (SRF) PLL. The experiments validate the correctness of the theoretical analysis.\",\"PeriodicalId\":231392,\"journal\":{\"name\":\"2023 IEEE International Conference on Power Science and Technology (ICPST)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE International Conference on Power Science and Technology (ICPST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPST56889.2023.10165059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE International Conference on Power Science and Technology (ICPST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST56889.2023.10165059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在弱电网条件下,并网逆变器的输出阻抗与电网阻抗耦合,导致电网电流质量较差。为了解决这一问题,提出了对称锁相环(PLL),它可以消除频率耦合并使系统模型具有对称性。虽然系统在稳态下性能良好,但目前逆变器在非理想条件下的特性尚不清楚。本文通过对对称锁相环在不同电网条件下逆变器性能的研究发现,与同步参考框架锁相环相比,对称锁相环的动态和稳态特性都变差了。实验验证了理论分析的正确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characteristics Analysis of Three-Phase Symmetrical Phase-Locked Loop under Non-Ideal Grid Conditions
Under weak grids, the output impedance of grid-connected inverter is coupled with the grid impedance, leading to poor quality of the grid current. To address this issue, the symmetrical phase-locked loop (PLL) has been proposed which can eliminate the frequency coupling and attribute the system model to be symmetrical. Although the system performances well under steady state, the characteristics of the inverter is unclear under non-ideal conditions at present. In this article, by investigating the inverter performance with the symmetrical PLL under different grid conditions, it is founded that both the dynamic and steady-state characteristics become worse compared to that with synchronous reference frame (SRF) PLL. The experiments validate the correctness of the theoretical analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信