Justin D. Johnston, M. Porter, K. Corzine, T. Weatherford
{"title":"基于GaN - PN自由旋转二极管光发射传感的Buck变换器闭环电流控制","authors":"Justin D. Johnston, M. Porter, K. Corzine, T. Weatherford","doi":"10.1109/APEC43580.2023.10131525","DOIUrl":null,"url":null,"abstract":"This paper demonstrates the closed-loop control of a buck converter circuit using EL signals generated in a GaN PN diode, used as the freewheeling diode. A method of calibration of the EL signal based on utilizing the known duty cycle of the current drive waveform and the current amplitude is introduced to predict the rea- time current. A double-PI control architecture is used to implement closed-loop output voltage control with the EL signal. The closed-loop response shows good agreement and stable control with less than 6% error in steady-state. During step responses in load and setpoint, large settling times are observed and explained by limitations in the hardware used for signal detection and current estimation via the EL signal. A discussion is presented for improving the response time and accuracy of EL based current estimation for better converter control performance.","PeriodicalId":151216,"journal":{"name":"2023 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Closed-Loop Current Control of a Buck Converter via Sensing of Optical Emission from a GaN PN Freewheeling Diode\",\"authors\":\"Justin D. Johnston, M. Porter, K. Corzine, T. Weatherford\",\"doi\":\"10.1109/APEC43580.2023.10131525\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper demonstrates the closed-loop control of a buck converter circuit using EL signals generated in a GaN PN diode, used as the freewheeling diode. A method of calibration of the EL signal based on utilizing the known duty cycle of the current drive waveform and the current amplitude is introduced to predict the rea- time current. A double-PI control architecture is used to implement closed-loop output voltage control with the EL signal. The closed-loop response shows good agreement and stable control with less than 6% error in steady-state. During step responses in load and setpoint, large settling times are observed and explained by limitations in the hardware used for signal detection and current estimation via the EL signal. A discussion is presented for improving the response time and accuracy of EL based current estimation for better converter control performance.\",\"PeriodicalId\":151216,\"journal\":{\"name\":\"2023 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC43580.2023.10131525\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC43580.2023.10131525","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Closed-Loop Current Control of a Buck Converter via Sensing of Optical Emission from a GaN PN Freewheeling Diode
This paper demonstrates the closed-loop control of a buck converter circuit using EL signals generated in a GaN PN diode, used as the freewheeling diode. A method of calibration of the EL signal based on utilizing the known duty cycle of the current drive waveform and the current amplitude is introduced to predict the rea- time current. A double-PI control architecture is used to implement closed-loop output voltage control with the EL signal. The closed-loop response shows good agreement and stable control with less than 6% error in steady-state. During step responses in load and setpoint, large settling times are observed and explained by limitations in the hardware used for signal detection and current estimation via the EL signal. A discussion is presented for improving the response time and accuracy of EL based current estimation for better converter control performance.