暂态和稳态电压暂降源定位方法的性能

Younes Mohammadi, M. Bollen
{"title":"暂态和稳态电压暂降源定位方法的性能","authors":"Younes Mohammadi, M. Bollen","doi":"10.1109/ICHQP53011.2022.9808649","DOIUrl":null,"url":null,"abstract":"Online locating of voltage sag sources requires fast and accurate methods. In this context, this paper describes and compares the positive-sequence phasor-based (PB) and instantaneous-based (IB) methods during both transient and steady-state periods of voltage sags caused by grid faults and transformer energizing (TE). The methods are evaluated by applying 1992 voltage sags in a Brazilian power network. For fault cases, PB methods work better than IB. Some methods perform well within the transient period, and some do not work good enough and need improvements for online applications. For TE cases, IB methods are ahead of PB and most IB methods work very well in a half-cycle window of the transient period, whereas the PB methods must be improved. Regardless of the sag sources, the real current component method using IB values during the half-cycle window of transient period is the best method currently available, which can be used in online applications.","PeriodicalId":249133,"journal":{"name":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Voltage Sag Source Location Methods' Performance during Transient and Steady-state Periods\",\"authors\":\"Younes Mohammadi, M. Bollen\",\"doi\":\"10.1109/ICHQP53011.2022.9808649\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Online locating of voltage sag sources requires fast and accurate methods. In this context, this paper describes and compares the positive-sequence phasor-based (PB) and instantaneous-based (IB) methods during both transient and steady-state periods of voltage sags caused by grid faults and transformer energizing (TE). The methods are evaluated by applying 1992 voltage sags in a Brazilian power network. For fault cases, PB methods work better than IB. Some methods perform well within the transient period, and some do not work good enough and need improvements for online applications. For TE cases, IB methods are ahead of PB and most IB methods work very well in a half-cycle window of the transient period, whereas the PB methods must be improved. Regardless of the sag sources, the real current component method using IB values during the half-cycle window of transient period is the best method currently available, which can be used in online applications.\",\"PeriodicalId\":249133,\"journal\":{\"name\":\"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP53011.2022.9808649\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP53011.2022.9808649","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在线定位电压凹陷源需要快速准确的方法。在此背景下,本文描述并比较了在电网故障和变压器通电(TE)引起的暂态和稳态电压跌落期间基于正序相量(PB)和基于瞬时(IB)的方法。以1992年巴西电网电压跌落为例,对这些方法进行了评价。对于故障情况,PB方法的性能优于IB方法,有些方法在暂态期内性能良好,有些方法在在线应用时性能不够好,需要改进。对于TE情况,IB方法优于PB方法,并且大多数IB方法在瞬态半周期窗口内工作良好,而PB方法有待改进。无论凹陷源如何,利用瞬态半周窗口内的IB值的真实电流分量法是目前可用的最佳方法,可用于在线应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Voltage Sag Source Location Methods' Performance during Transient and Steady-state Periods
Online locating of voltage sag sources requires fast and accurate methods. In this context, this paper describes and compares the positive-sequence phasor-based (PB) and instantaneous-based (IB) methods during both transient and steady-state periods of voltage sags caused by grid faults and transformer energizing (TE). The methods are evaluated by applying 1992 voltage sags in a Brazilian power network. For fault cases, PB methods work better than IB. Some methods perform well within the transient period, and some do not work good enough and need improvements for online applications. For TE cases, IB methods are ahead of PB and most IB methods work very well in a half-cycle window of the transient period, whereas the PB methods must be improved. Regardless of the sag sources, the real current component method using IB values during the half-cycle window of transient period is the best method currently available, which can be used in online applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信