轨道开关容错驱动的仿真研究

Linxiao Li, Saikat Dutta, R. Dixon, E. Stewart
{"title":"轨道开关容错驱动的仿真研究","authors":"Linxiao Li, Saikat Dutta, R. Dixon, E. Stewart","doi":"10.1109/Control55989.2022.9781361","DOIUrl":null,"url":null,"abstract":"Track switches (also known as \"point\" or \"turnout\") are essential to the railway system and provide route flexibility by allowing vehicles to move between tracks on the network. However, the single actuators in the current switch technology mean that a single actuator fault will result in the failure of the switch (and the concomitant delays to trains waiting to pass the switch). This paper focuses on providing redundant actuation through an approach known as High Redundancy Actuation (HRA), which might allow track switches to remain operational after failure in actuator elements. The paper also proposes the use of closed-loop control (track switches are usually operated open-loop). In the paper, we introduce a model of a C-type switch and validate it against results from a previous paper. This model is then used combined with an HRA of nine elements (3x3). Two closed-loop controllers are then proposed for each of the single actuator and the HRA actuator system. The findings indicate that closed-loop control on its own has some benefits. However, when combined with HRA, the resulting system is able to tolerate a number of faults in the actuator subsystems, creating an effective graceful degradation rather than the sudden failure with a traditional single actuator.","PeriodicalId":101892,"journal":{"name":"2022 UKACC 13th International Conference on Control (CONTROL)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Fault Tolerant Actuation of a Railway Track Switch: a Simulation Study\",\"authors\":\"Linxiao Li, Saikat Dutta, R. Dixon, E. Stewart\",\"doi\":\"10.1109/Control55989.2022.9781361\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Track switches (also known as \\\"point\\\" or \\\"turnout\\\") are essential to the railway system and provide route flexibility by allowing vehicles to move between tracks on the network. However, the single actuators in the current switch technology mean that a single actuator fault will result in the failure of the switch (and the concomitant delays to trains waiting to pass the switch). This paper focuses on providing redundant actuation through an approach known as High Redundancy Actuation (HRA), which might allow track switches to remain operational after failure in actuator elements. The paper also proposes the use of closed-loop control (track switches are usually operated open-loop). In the paper, we introduce a model of a C-type switch and validate it against results from a previous paper. This model is then used combined with an HRA of nine elements (3x3). Two closed-loop controllers are then proposed for each of the single actuator and the HRA actuator system. The findings indicate that closed-loop control on its own has some benefits. However, when combined with HRA, the resulting system is able to tolerate a number of faults in the actuator subsystems, creating an effective graceful degradation rather than the sudden failure with a traditional single actuator.\",\"PeriodicalId\":101892,\"journal\":{\"name\":\"2022 UKACC 13th International Conference on Control (CONTROL)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 UKACC 13th International Conference on Control (CONTROL)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/Control55989.2022.9781361\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 UKACC 13th International Conference on Control (CONTROL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/Control55989.2022.9781361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

轨道开关(也被称为“点”或“道岔”)对铁路系统至关重要,并通过允许车辆在网络上的轨道之间移动提供路线灵活性。然而,在目前的开关技术中,单执行器意味着单个执行器故障将导致开关失效(并伴随等待通过开关的列车延误)。本文的重点是通过一种称为高冗余驱动(HRA)的方法提供冗余驱动,该方法可能允许轨迹开关在执行器元件失效后保持运行。本文还提出了采用闭环控制(轨道开关通常是开环操作)。本文介绍了一种c型开关的模型,并与前人的结果进行了验证。然后将该模型与9个元素(3x3)的HRA结合使用。然后针对单个作动器和HRA作动器系统分别提出了两个闭环控制器。研究结果表明,闭环控制本身有一些好处。然而,当与HRA结合使用时,所得到的系统能够容忍执行器子系统中的许多故障,从而产生有效的优雅退化,而不是传统的单个执行器的突然故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fault Tolerant Actuation of a Railway Track Switch: a Simulation Study
Track switches (also known as "point" or "turnout") are essential to the railway system and provide route flexibility by allowing vehicles to move between tracks on the network. However, the single actuators in the current switch technology mean that a single actuator fault will result in the failure of the switch (and the concomitant delays to trains waiting to pass the switch). This paper focuses on providing redundant actuation through an approach known as High Redundancy Actuation (HRA), which might allow track switches to remain operational after failure in actuator elements. The paper also proposes the use of closed-loop control (track switches are usually operated open-loop). In the paper, we introduce a model of a C-type switch and validate it against results from a previous paper. This model is then used combined with an HRA of nine elements (3x3). Two closed-loop controllers are then proposed for each of the single actuator and the HRA actuator system. The findings indicate that closed-loop control on its own has some benefits. However, when combined with HRA, the resulting system is able to tolerate a number of faults in the actuator subsystems, creating an effective graceful degradation rather than the sudden failure with a traditional single actuator.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信