N. H. Ramlan, N. Azli, Hanifah Jambari, N. M. Nordin
{"title":"级联h桥多电平逆变器互连与阻尼分配无源控制器","authors":"N. H. Ramlan, N. Azli, Hanifah Jambari, N. M. Nordin","doi":"10.1109/CENCON.2017.8262451","DOIUrl":null,"url":null,"abstract":"This paper presents an interconnection and damping assignment passivity-based controller (IDA-PBC) for Cascaded H-bridge Multilevel Inverter (CHMI). The main objective of this paper is to investigate the output voltage waveform regulation with low harmonic distortion. The circuit is modeled as a port-controlled Hamiltonian (PCH) system through average modeling. IDA-PBC is capable to regulate the voltage during various loading condition. The proposed control scheme is compared to the conventional double-loop PI controller and verified by detailed simulation analysis using MATLAB-Simulink software. Simulation results show that the proposed algorithm ensures fast response time and stability of the system during load change while maintaining low harmonic distortion.","PeriodicalId":275077,"journal":{"name":"2017 IEEE Conference on Energy Conversion (CENCON)","volume":"99 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Interconnection and damping assignment passivity-based controller for cascaded H-bridge multilevel inverter\",\"authors\":\"N. H. Ramlan, N. Azli, Hanifah Jambari, N. M. Nordin\",\"doi\":\"10.1109/CENCON.2017.8262451\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an interconnection and damping assignment passivity-based controller (IDA-PBC) for Cascaded H-bridge Multilevel Inverter (CHMI). The main objective of this paper is to investigate the output voltage waveform regulation with low harmonic distortion. The circuit is modeled as a port-controlled Hamiltonian (PCH) system through average modeling. IDA-PBC is capable to regulate the voltage during various loading condition. The proposed control scheme is compared to the conventional double-loop PI controller and verified by detailed simulation analysis using MATLAB-Simulink software. Simulation results show that the proposed algorithm ensures fast response time and stability of the system during load change while maintaining low harmonic distortion.\",\"PeriodicalId\":275077,\"journal\":{\"name\":\"2017 IEEE Conference on Energy Conversion (CENCON)\",\"volume\":\"99 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Conference on Energy Conversion (CENCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CENCON.2017.8262451\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Conference on Energy Conversion (CENCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CENCON.2017.8262451","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Interconnection and damping assignment passivity-based controller for cascaded H-bridge multilevel inverter
This paper presents an interconnection and damping assignment passivity-based controller (IDA-PBC) for Cascaded H-bridge Multilevel Inverter (CHMI). The main objective of this paper is to investigate the output voltage waveform regulation with low harmonic distortion. The circuit is modeled as a port-controlled Hamiltonian (PCH) system through average modeling. IDA-PBC is capable to regulate the voltage during various loading condition. The proposed control scheme is compared to the conventional double-loop PI controller and verified by detailed simulation analysis using MATLAB-Simulink software. Simulation results show that the proposed algorithm ensures fast response time and stability of the system during load change while maintaining low harmonic distortion.