{"title":"心脏除颤过程中单极电压测量计算心外膜电位梯度场的错误","authors":"S.F. ldriss, R. Ideker, P. Wolf, W.M. Smith","doi":"10.1109/IEMBS.1991.684147","DOIUrl":null,"url":null,"abstract":"We examined the errors generated when calculating the magnitude of the epicardial potential gradient using voltages recorded from three unipolar electrodes in a fixed triangular geometry on the epicardial surface. The error sensitivity of the gradient calculation increases significantly with decreasing electrode separation and increasing common-mode voltage. For example, a mean error in calculated gradient magnitude of 67% results when measuring a 5 V/cm gradient at 50 V common-mode with 2 mm interelectrode spacing and random 1 % voltage error. Optimization of interelectrode spacing and common-mode voltage to reduce overall error is essential for accurate measurement of low magnitude epicardial gradients.","PeriodicalId":297811,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991","volume":"50 8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Errors In Calculating The Epicardial Potential Gradient Field From Unipolar Voltage Measurements During Cardiac Defibrillation\",\"authors\":\"S.F. ldriss, R. Ideker, P. Wolf, W.M. Smith\",\"doi\":\"10.1109/IEMBS.1991.684147\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We examined the errors generated when calculating the magnitude of the epicardial potential gradient using voltages recorded from three unipolar electrodes in a fixed triangular geometry on the epicardial surface. The error sensitivity of the gradient calculation increases significantly with decreasing electrode separation and increasing common-mode voltage. For example, a mean error in calculated gradient magnitude of 67% results when measuring a 5 V/cm gradient at 50 V common-mode with 2 mm interelectrode spacing and random 1 % voltage error. Optimization of interelectrode spacing and common-mode voltage to reduce overall error is essential for accurate measurement of low magnitude epicardial gradients.\",\"PeriodicalId\":297811,\"journal\":{\"name\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991\",\"volume\":\"50 8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1991.684147\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1991.684147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Errors In Calculating The Epicardial Potential Gradient Field From Unipolar Voltage Measurements During Cardiac Defibrillation
We examined the errors generated when calculating the magnitude of the epicardial potential gradient using voltages recorded from three unipolar electrodes in a fixed triangular geometry on the epicardial surface. The error sensitivity of the gradient calculation increases significantly with decreasing electrode separation and increasing common-mode voltage. For example, a mean error in calculated gradient magnitude of 67% results when measuring a 5 V/cm gradient at 50 V common-mode with 2 mm interelectrode spacing and random 1 % voltage error. Optimization of interelectrode spacing and common-mode voltage to reduce overall error is essential for accurate measurement of low magnitude epicardial gradients.