{"title":"实验室规模微电网的建设、运行和控制","authors":"Zhangang Yang, C. Yanbo, Chengshan Wang","doi":"10.1109/SUPERGEN.2009.5348214","DOIUrl":null,"url":null,"abstract":"To provide a test facility for possible demonstrations of advanced distributed generation system integration strategies, a single-phase laboratory-scale Microgrid system is set up. Two distributed generators are included in this Microgrid, a photovoltaic simulator and a wind turbine simulator. Both of them are connected to the AC grid via flexible power electronic interface respectively. For stable collaborative operation, a battery energy storage interfaced with a bi-directional inverter is necessary in this Microgrid. In the grid-connected mode, both the distributed generators converters and the bi-directional inverter are the grid-following unit. While switching from grid-connected mode to islanded mode, the bi-directional inverter is setting the voltage and frequency of the Microgrid through absorbing or releasing energy. The operation experimental results show that the laboratory-scale Microgrid system can operate in grid-connected or islanded mode, with a seamless transfer from one mode to the other, and hence increase the reliability of energy supplies.","PeriodicalId":250585,"journal":{"name":"2009 International Conference on Sustainable Power Generation and Supply","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Construction, operation and control of a laboratory-scale microgrid\",\"authors\":\"Zhangang Yang, C. Yanbo, Chengshan Wang\",\"doi\":\"10.1109/SUPERGEN.2009.5348214\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To provide a test facility for possible demonstrations of advanced distributed generation system integration strategies, a single-phase laboratory-scale Microgrid system is set up. Two distributed generators are included in this Microgrid, a photovoltaic simulator and a wind turbine simulator. Both of them are connected to the AC grid via flexible power electronic interface respectively. For stable collaborative operation, a battery energy storage interfaced with a bi-directional inverter is necessary in this Microgrid. In the grid-connected mode, both the distributed generators converters and the bi-directional inverter are the grid-following unit. While switching from grid-connected mode to islanded mode, the bi-directional inverter is setting the voltage and frequency of the Microgrid through absorbing or releasing energy. The operation experimental results show that the laboratory-scale Microgrid system can operate in grid-connected or islanded mode, with a seamless transfer from one mode to the other, and hence increase the reliability of energy supplies.\",\"PeriodicalId\":250585,\"journal\":{\"name\":\"2009 International Conference on Sustainable Power Generation and Supply\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Conference on Sustainable Power Generation and Supply\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SUPERGEN.2009.5348214\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Sustainable Power Generation and Supply","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SUPERGEN.2009.5348214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Construction, operation and control of a laboratory-scale microgrid
To provide a test facility for possible demonstrations of advanced distributed generation system integration strategies, a single-phase laboratory-scale Microgrid system is set up. Two distributed generators are included in this Microgrid, a photovoltaic simulator and a wind turbine simulator. Both of them are connected to the AC grid via flexible power electronic interface respectively. For stable collaborative operation, a battery energy storage interfaced with a bi-directional inverter is necessary in this Microgrid. In the grid-connected mode, both the distributed generators converters and the bi-directional inverter are the grid-following unit. While switching from grid-connected mode to islanded mode, the bi-directional inverter is setting the voltage and frequency of the Microgrid through absorbing or releasing energy. The operation experimental results show that the laboratory-scale Microgrid system can operate in grid-connected or islanded mode, with a seamless transfer from one mode to the other, and hence increase the reliability of energy supplies.