调质阻尼器与流体粘性阻尼器对两种不同模式G+15层建筑地震响应影响的对比研究

Yogeshwari Sahu, Mr. Dushyant Sahu
{"title":"调质阻尼器与流体粘性阻尼器对两种不同模式G+15层建筑地震响应影响的对比研究","authors":"Yogeshwari Sahu, Mr. Dushyant Sahu","doi":"10.30732/csvturj.20211001009","DOIUrl":null,"url":null,"abstract":"During an earthquake phase, dampers are used to dissipate energy as well as stop the Deformation of the Structure. Dampers help in reducing buckling and failure of columns and beams by increasing the stability of the frame. During earthquakes, high-rise buildings are prone to destruction or significant deformation. Use of dampers reduce the shaking of reinforcement cement concrete structures during an earthquake. We used and analyzed various types of dampers to determine the suitability of various types dampers during an earthquake. An empirical study has been performed for the comparative review of two dampers: a fluid viscous damper and a tuned mass damper used for multi-story cement concrete building reinforcement. Time History Method is applied to assess the seismic behaviour of a G+15 storey building with and without dampers. The earthquake load is applied in both the x and y directions for research. TheIS1893:2002(part 1) code is used in conjunction with the ETABS 2018 version18.1.1 package for the purpose of analysis. The findings of these experiments are discussed in terms of numerous parameters such as maximal absolute displacement, absolute acceleration, absolute velocity, storey shear, storey drift, storey stiffness, and modal participation mass ratio in order to compare these parameters. Two kinds of dampers are used to dissipate seismic energy. In this article, a comparison of two different buildings of different bay sizes (5mx5m & 6mx6m) is used, as well as a comparative analysis of various parameters using Tuned Mass Damper and Fluid Viscous Damper.","PeriodicalId":234213,"journal":{"name":"CSVTU Research Journal on Engineering and Technology","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Study: The Effect of Tuned Mass Damper and Fluid Viscous Damper on The Response of Two Different Models of G+15 Storey Building During Earthquake\",\"authors\":\"Yogeshwari Sahu, Mr. Dushyant Sahu\",\"doi\":\"10.30732/csvturj.20211001009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"During an earthquake phase, dampers are used to dissipate energy as well as stop the Deformation of the Structure. Dampers help in reducing buckling and failure of columns and beams by increasing the stability of the frame. During earthquakes, high-rise buildings are prone to destruction or significant deformation. Use of dampers reduce the shaking of reinforcement cement concrete structures during an earthquake. We used and analyzed various types of dampers to determine the suitability of various types dampers during an earthquake. An empirical study has been performed for the comparative review of two dampers: a fluid viscous damper and a tuned mass damper used for multi-story cement concrete building reinforcement. Time History Method is applied to assess the seismic behaviour of a G+15 storey building with and without dampers. The earthquake load is applied in both the x and y directions for research. TheIS1893:2002(part 1) code is used in conjunction with the ETABS 2018 version18.1.1 package for the purpose of analysis. The findings of these experiments are discussed in terms of numerous parameters such as maximal absolute displacement, absolute acceleration, absolute velocity, storey shear, storey drift, storey stiffness, and modal participation mass ratio in order to compare these parameters. Two kinds of dampers are used to dissipate seismic energy. In this article, a comparison of two different buildings of different bay sizes (5mx5m & 6mx6m) is used, as well as a comparative analysis of various parameters using Tuned Mass Damper and Fluid Viscous Damper.\",\"PeriodicalId\":234213,\"journal\":{\"name\":\"CSVTU Research Journal on Engineering and Technology\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CSVTU Research Journal on Engineering and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30732/csvturj.20211001009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CSVTU Research Journal on Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30732/csvturj.20211001009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative Study: The Effect of Tuned Mass Damper and Fluid Viscous Damper on The Response of Two Different Models of G+15 Storey Building During Earthquake
During an earthquake phase, dampers are used to dissipate energy as well as stop the Deformation of the Structure. Dampers help in reducing buckling and failure of columns and beams by increasing the stability of the frame. During earthquakes, high-rise buildings are prone to destruction or significant deformation. Use of dampers reduce the shaking of reinforcement cement concrete structures during an earthquake. We used and analyzed various types of dampers to determine the suitability of various types dampers during an earthquake. An empirical study has been performed for the comparative review of two dampers: a fluid viscous damper and a tuned mass damper used for multi-story cement concrete building reinforcement. Time History Method is applied to assess the seismic behaviour of a G+15 storey building with and without dampers. The earthquake load is applied in both the x and y directions for research. TheIS1893:2002(part 1) code is used in conjunction with the ETABS 2018 version18.1.1 package for the purpose of analysis. The findings of these experiments are discussed in terms of numerous parameters such as maximal absolute displacement, absolute acceleration, absolute velocity, storey shear, storey drift, storey stiffness, and modal participation mass ratio in order to compare these parameters. Two kinds of dampers are used to dissipate seismic energy. In this article, a comparison of two different buildings of different bay sizes (5mx5m & 6mx6m) is used, as well as a comparative analysis of various parameters using Tuned Mass Damper and Fluid Viscous Damper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信