{"title":"基于电枢电流轨迹的无机械传感器永磁同步电机转子位置估计方法","authors":"S. Kondo, A. Takahashi, T. Nishida","doi":"10.1109/IAS.1995.530283","DOIUrl":null,"url":null,"abstract":"This paper describes a new method of estimating the initial rotor position of a permanent magnet (PM) motor without turning the rotor. At the stand still, the saliency of the PM motor makes the locus of the armature current-vector an oval when the armature voltage is a 3-phase balanced sine wave applied by a PWM inverter. The major diameter direction of the current-vector locus gives information on the rotor direction. The shift of the current-vector locus caused by magnetic saturation makes it possible to identify the direction of the rotor magnet N-pole. The proposed method to estimate the rotor position was verified by experimental results of a 100 W PM motor.","PeriodicalId":117576,"journal":{"name":"IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting","volume":"431 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"55","resultStr":"{\"title\":\"Armature current locus based estimation method of rotor position of permanent magnet synchronous motor without mechanical sensor\",\"authors\":\"S. Kondo, A. Takahashi, T. Nishida\",\"doi\":\"10.1109/IAS.1995.530283\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a new method of estimating the initial rotor position of a permanent magnet (PM) motor without turning the rotor. At the stand still, the saliency of the PM motor makes the locus of the armature current-vector an oval when the armature voltage is a 3-phase balanced sine wave applied by a PWM inverter. The major diameter direction of the current-vector locus gives information on the rotor direction. The shift of the current-vector locus caused by magnetic saturation makes it possible to identify the direction of the rotor magnet N-pole. The proposed method to estimate the rotor position was verified by experimental results of a 100 W PM motor.\",\"PeriodicalId\":117576,\"journal\":{\"name\":\"IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting\",\"volume\":\"431 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"55\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1995.530283\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1995.530283","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Armature current locus based estimation method of rotor position of permanent magnet synchronous motor without mechanical sensor
This paper describes a new method of estimating the initial rotor position of a permanent magnet (PM) motor without turning the rotor. At the stand still, the saliency of the PM motor makes the locus of the armature current-vector an oval when the armature voltage is a 3-phase balanced sine wave applied by a PWM inverter. The major diameter direction of the current-vector locus gives information on the rotor direction. The shift of the current-vector locus caused by magnetic saturation makes it possible to identify the direction of the rotor magnet N-pole. The proposed method to estimate the rotor position was verified by experimental results of a 100 W PM motor.