Lei Wang, Hongtao Huang, Xianlin Pan, Lijuan Liu, Min Li, Zuliang Lu
{"title":"一种数字输入电能计量标准","authors":"Lei Wang, Hongtao Huang, Xianlin Pan, Lijuan Liu, Min Li, Zuliang Lu","doi":"10.1109/CPEM.2014.6898382","DOIUrl":null,"url":null,"abstract":"A measurement standard of digital input electricity energy based on the analog based method was developed in NIM China. The resistive voltage divider and current shunt with capacitor compensation were adopted; the non-integral period sampling technology was used to reduce the algorithm error. The working frequency of this standard is 45 to 65 Hz, the voltage range is 60 V to 380 V and current range is 0.2 A to 20 A.","PeriodicalId":256575,"journal":{"name":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A digital input electricity energy measurement standard\",\"authors\":\"Lei Wang, Hongtao Huang, Xianlin Pan, Lijuan Liu, Min Li, Zuliang Lu\",\"doi\":\"10.1109/CPEM.2014.6898382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A measurement standard of digital input electricity energy based on the analog based method was developed in NIM China. The resistive voltage divider and current shunt with capacitor compensation were adopted; the non-integral period sampling technology was used to reduce the algorithm error. The working frequency of this standard is 45 to 65 Hz, the voltage range is 60 V to 380 V and current range is 0.2 A to 20 A.\",\"PeriodicalId\":256575,\"journal\":{\"name\":\"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2014.6898382\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2014.6898382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
在模拟方法的基础上,制定了数字输入电能的测量标准。采用电容补偿的电阻分压器和电流分流;采用非积分周期采样技术减小了算法误差。本标准的工作频率为45 ~ 65hz,电压范围为60v ~ 380v,电流范围为0.2 A ~ 20a。
A digital input electricity energy measurement standard
A measurement standard of digital input electricity energy based on the analog based method was developed in NIM China. The resistive voltage divider and current shunt with capacitor compensation were adopted; the non-integral period sampling technology was used to reduce the algorithm error. The working frequency of this standard is 45 to 65 Hz, the voltage range is 60 V to 380 V and current range is 0.2 A to 20 A.