断裙和污染对帽针玻璃绝缘子电压分布的影响

C. Mateus, F. Barata, R. Luís
{"title":"断裙和污染对帽针玻璃绝缘子电压分布的影响","authors":"C. Mateus, F. Barata, R. Luís","doi":"10.1109/CPE-POWERENG48600.2020.9161644","DOIUrl":null,"url":null,"abstract":"Cap and Pin insulators are key elements on aerial electric power transmission lines in which their performance is subject to the environmental elements, like pollution and/or humidity. Furthermore, a broken insulator (stub) on an insulator string may change the voltage distribution along the chain. This paper goal is to study the effects of the voltage distribution along with tempered glass cap and pin insulator string in the presence of broken skirts as well contamination by pollution, using for that purpose a finite element software. This paper presents the voltage distribution profile across single and fourteen units of glass insulator string with stubs at distinct locations as well for the presence of contamination by pollution. It is concluded that the presence of pollution on a string with stubs will alter and exacerbate the increase of electrical potential effect due to the presence of stubs.","PeriodicalId":111104,"journal":{"name":"2020 IEEE 14th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effects of Broken Skirts and Pollution on Voltage Distribution for Cap and Pin Glass Insulators\",\"authors\":\"C. Mateus, F. Barata, R. Luís\",\"doi\":\"10.1109/CPE-POWERENG48600.2020.9161644\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cap and Pin insulators are key elements on aerial electric power transmission lines in which their performance is subject to the environmental elements, like pollution and/or humidity. Furthermore, a broken insulator (stub) on an insulator string may change the voltage distribution along the chain. This paper goal is to study the effects of the voltage distribution along with tempered glass cap and pin insulator string in the presence of broken skirts as well contamination by pollution, using for that purpose a finite element software. This paper presents the voltage distribution profile across single and fourteen units of glass insulator string with stubs at distinct locations as well for the presence of contamination by pollution. It is concluded that the presence of pollution on a string with stubs will alter and exacerbate the increase of electrical potential effect due to the presence of stubs.\",\"PeriodicalId\":111104,\"journal\":{\"name\":\"2020 IEEE 14th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 14th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPE-POWERENG48600.2020.9161644\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 14th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE-POWERENG48600.2020.9161644","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

Cap和Pin绝缘子是架空输电线路上的关键元件,其性能受环境因素(如污染和/或湿度)的影响。此外,绝缘子串上的断绝缘子(短段)可能会改变沿链的电压分布。本文的目的是研究钢化玻璃帽和引脚绝缘子串在裙边破损和污染情况下电压分布的影响,为此使用了一个有限元软件。本文介绍了在不同位置的单个和14个单元的玻璃绝缘子串上的电压分布曲线,以及污染污染的存在。结果表明,有桩的管柱上存在污染会改变和加剧由于桩的存在而引起的电势效应的增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of Broken Skirts and Pollution on Voltage Distribution for Cap and Pin Glass Insulators
Cap and Pin insulators are key elements on aerial electric power transmission lines in which their performance is subject to the environmental elements, like pollution and/or humidity. Furthermore, a broken insulator (stub) on an insulator string may change the voltage distribution along the chain. This paper goal is to study the effects of the voltage distribution along with tempered glass cap and pin insulator string in the presence of broken skirts as well contamination by pollution, using for that purpose a finite element software. This paper presents the voltage distribution profile across single and fourteen units of glass insulator string with stubs at distinct locations as well for the presence of contamination by pollution. It is concluded that the presence of pollution on a string with stubs will alter and exacerbate the increase of electrical potential effect due to the presence of stubs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信