用降阶karhunen - lo基压缩mr测温图像

Ran Niu, M. Skliar
{"title":"用降阶karhunen - lo<e:1>基压缩mr测温图像","authors":"Ran Niu, M. Skliar","doi":"10.1109/WCICA.2012.6359245","DOIUrl":null,"url":null,"abstract":"In this paper, we develop an approach to achieve MR thermal image compression by exploiting the spatial correlations of image voxels during thermal treatment. A set of reduced-order basis was identified using Karhunen-Loève (KL) decomposition of MR thermal images. Each image can be compressed with a relative small number of identified KL basis functions. The proposed approach can be used in real-time compression of imaging data in order to minimize a potentially massive amount of information that must be exchanged between the MR scanner and the treatment controller, and reduce computer storage requirements during thermal treatment. Simulation and MR thermometry experimental results demonstrate that the proposed image compression method is also effective in suppressing high spatial-frequency MR measurement noises.","PeriodicalId":114901,"journal":{"name":"Proceedings of the 10th World Congress on Intelligent Control and Automation","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Compression of MR-Thermometry images using reduced-order Karhunen-Loève basis\",\"authors\":\"Ran Niu, M. Skliar\",\"doi\":\"10.1109/WCICA.2012.6359245\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we develop an approach to achieve MR thermal image compression by exploiting the spatial correlations of image voxels during thermal treatment. A set of reduced-order basis was identified using Karhunen-Loève (KL) decomposition of MR thermal images. Each image can be compressed with a relative small number of identified KL basis functions. The proposed approach can be used in real-time compression of imaging data in order to minimize a potentially massive amount of information that must be exchanged between the MR scanner and the treatment controller, and reduce computer storage requirements during thermal treatment. Simulation and MR thermometry experimental results demonstrate that the proposed image compression method is also effective in suppressing high spatial-frequency MR measurement noises.\",\"PeriodicalId\":114901,\"journal\":{\"name\":\"Proceedings of the 10th World Congress on Intelligent Control and Automation\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 10th World Congress on Intelligent Control and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WCICA.2012.6359245\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 10th World Congress on Intelligent Control and Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WCICA.2012.6359245","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在本文中,我们开发了一种通过利用图像体素在热处理过程中的空间相关性来实现MR热图像压缩的方法。采用karhunen - lo (KL)分解方法对MR热图像进行了降阶基识别。每个图像可以用相对较少数量的识别KL基函数进行压缩。该方法可用于实时压缩成像数据,以最大限度地减少mri扫描仪和处理控制器之间必须交换的潜在大量信息,并减少热处理过程中的计算机存储需求。仿真和磁共振测温实验结果表明,所提出的图像压缩方法能够有效抑制高空间频率的磁共振测量噪声。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Compression of MR-Thermometry images using reduced-order Karhunen-Loève basis
In this paper, we develop an approach to achieve MR thermal image compression by exploiting the spatial correlations of image voxels during thermal treatment. A set of reduced-order basis was identified using Karhunen-Loève (KL) decomposition of MR thermal images. Each image can be compressed with a relative small number of identified KL basis functions. The proposed approach can be used in real-time compression of imaging data in order to minimize a potentially massive amount of information that must be exchanged between the MR scanner and the treatment controller, and reduce computer storage requirements during thermal treatment. Simulation and MR thermometry experimental results demonstrate that the proposed image compression method is also effective in suppressing high spatial-frequency MR measurement noises.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信