{"title":"一种用于功率因数校正的两相交错CCM/DCM边界模式升压变换器的SFVM控制新方案","authors":"Chung-Ping Ku, Dan Y. Chen, Chin Yuan Liu","doi":"10.1109/ECCE.2010.5617894","DOIUrl":null,"url":null,"abstract":"This paper presents an open-loop synchronized-off voltage mode (SFVM) control scheme for a two-phase interleaved boost converter with master-slave strategy for PFC applications. Interleaving CCM/DCM boundary mode boost converters, however, is complicated because of the variable-frequencies nature of the operation. The problem of current divergence is often encountered in the Slave converter. In this paper, a novel on-time adjustment scheme of Slave converter is presented to stabilize the interleaved converter without using any phase-lock loop, multiplier or inductor current sensing. A circuit was proposed to verify the strategy by simulations.","PeriodicalId":161915,"journal":{"name":"2010 IEEE Energy Conversion Congress and Exposition","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A novel SFVM control scheme for two-phase interleaved CCM/DCM boundary mode boost converter in power factor correction applications\",\"authors\":\"Chung-Ping Ku, Dan Y. Chen, Chin Yuan Liu\",\"doi\":\"10.1109/ECCE.2010.5617894\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an open-loop synchronized-off voltage mode (SFVM) control scheme for a two-phase interleaved boost converter with master-slave strategy for PFC applications. Interleaving CCM/DCM boundary mode boost converters, however, is complicated because of the variable-frequencies nature of the operation. The problem of current divergence is often encountered in the Slave converter. In this paper, a novel on-time adjustment scheme of Slave converter is presented to stabilize the interleaved converter without using any phase-lock loop, multiplier or inductor current sensing. A circuit was proposed to verify the strategy by simulations.\",\"PeriodicalId\":161915,\"journal\":{\"name\":\"2010 IEEE Energy Conversion Congress and Exposition\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE Energy Conversion Congress and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE.2010.5617894\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE Energy Conversion Congress and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2010.5617894","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A novel SFVM control scheme for two-phase interleaved CCM/DCM boundary mode boost converter in power factor correction applications
This paper presents an open-loop synchronized-off voltage mode (SFVM) control scheme for a two-phase interleaved boost converter with master-slave strategy for PFC applications. Interleaving CCM/DCM boundary mode boost converters, however, is complicated because of the variable-frequencies nature of the operation. The problem of current divergence is often encountered in the Slave converter. In this paper, a novel on-time adjustment scheme of Slave converter is presented to stabilize the interleaved converter without using any phase-lock loop, multiplier or inductor current sensing. A circuit was proposed to verify the strategy by simulations.