用阵列微热膜传感器测量湍流通道壁面剪应力的评价

T. Yoshino, Yuji Suzuki, N. Kasagi, S. Kamiunten
{"title":"用阵列微热膜传感器测量湍流通道壁面剪应力的评价","authors":"T. Yoshino, Yuji Suzuki, N. Kasagi, S. Kamiunten","doi":"10.1615/tsfp2.990","DOIUrl":null,"url":null,"abstract":"Arrayed micro hot-film sensors for the measurement of the streamwise and spanwise wall shear stresses were developed and evaluated in a turbulent channel flow. The bandwidth of the sensor is found to be much narrower than previous estimates in the literature. A numerical analysis of the unsteady thermal field around the sensor chip is made in order to obtain a clue to design a hot-film shear stress sensor having higher frequency response. It is found that the phase lag of the thermal boundary layer above the hot-film and the indirect convective heat transfer through the diaphragm are responsible for the deteriorated sensor response.","PeriodicalId":438618,"journal":{"name":"Proceeding of Second Symposium on Turbulence and Shear Flow Phenomena","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Assessment of the wall shear stress measurement with arrayed micro hot-film sensors in a turbulent channel flow\",\"authors\":\"T. Yoshino, Yuji Suzuki, N. Kasagi, S. Kamiunten\",\"doi\":\"10.1615/tsfp2.990\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Arrayed micro hot-film sensors for the measurement of the streamwise and spanwise wall shear stresses were developed and evaluated in a turbulent channel flow. The bandwidth of the sensor is found to be much narrower than previous estimates in the literature. A numerical analysis of the unsteady thermal field around the sensor chip is made in order to obtain a clue to design a hot-film shear stress sensor having higher frequency response. It is found that the phase lag of the thermal boundary layer above the hot-film and the indirect convective heat transfer through the diaphragm are responsible for the deteriorated sensor response.\",\"PeriodicalId\":438618,\"journal\":{\"name\":\"Proceeding of Second Symposium on Turbulence and Shear Flow Phenomena\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceeding of Second Symposium on Turbulence and Shear Flow Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1615/tsfp2.990\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceeding of Second Symposium on Turbulence and Shear Flow Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1615/tsfp2.990","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

研制了用于测量湍流通道流向和展向壁面剪切应力的阵列微热膜传感器,并对其进行了评价。发现传感器的带宽比文献中先前的估计窄得多。对传感器芯片周围的非定常热场进行了数值分析,为设计具有更高频率响应的热膜剪切应力传感器提供了线索。发现热膜上方热边界层的相位滞后和通过隔膜的间接对流换热是传感器响应变差的主要原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of the wall shear stress measurement with arrayed micro hot-film sensors in a turbulent channel flow
Arrayed micro hot-film sensors for the measurement of the streamwise and spanwise wall shear stresses were developed and evaluated in a turbulent channel flow. The bandwidth of the sensor is found to be much narrower than previous estimates in the literature. A numerical analysis of the unsteady thermal field around the sensor chip is made in order to obtain a clue to design a hot-film shear stress sensor having higher frequency response. It is found that the phase lag of the thermal boundary layer above the hot-film and the indirect convective heat transfer through the diaphragm are responsible for the deteriorated sensor response.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信