基于锂离子的最佳尺寸网格界面屋顶光伏系统

J. S. Goud, Srikanth Tunga, Qumera Sultana, S. Bindu
{"title":"基于锂离子的最佳尺寸网格界面屋顶光伏系统","authors":"J. S. Goud, Srikanth Tunga, Qumera Sultana, S. Bindu","doi":"10.1109/ICEES.2016.7510651","DOIUrl":null,"url":null,"abstract":"Increase in power demand and insufficient power generation has lead to frequent power cuts, which have become a major concern for house owners. Due to falling PV panel prices and concerns over greenhouse gas emissions, lead acid based PV systems are gaining popularity for home electrification during power cuts. Lead acid battery used for energy storage has high recurring cost and adversely impact the environment, with hazardous compounds contaminating the environment on its improper disposal. To overcome this issue, an optimal method of PV sizing is implemented in this paper to reduce battery sizing in roof top PV systems and a suitable battery technology is adopted to reduce the total cost of ownership of the system.","PeriodicalId":308604,"journal":{"name":"2016 3rd International Conference on Electrical Energy Systems (ICEES)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Li-ion based optimally sized grid interfaced roof top PV system\",\"authors\":\"J. S. Goud, Srikanth Tunga, Qumera Sultana, S. Bindu\",\"doi\":\"10.1109/ICEES.2016.7510651\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Increase in power demand and insufficient power generation has lead to frequent power cuts, which have become a major concern for house owners. Due to falling PV panel prices and concerns over greenhouse gas emissions, lead acid based PV systems are gaining popularity for home electrification during power cuts. Lead acid battery used for energy storage has high recurring cost and adversely impact the environment, with hazardous compounds contaminating the environment on its improper disposal. To overcome this issue, an optimal method of PV sizing is implemented in this paper to reduce battery sizing in roof top PV systems and a suitable battery technology is adopted to reduce the total cost of ownership of the system.\",\"PeriodicalId\":308604,\"journal\":{\"name\":\"2016 3rd International Conference on Electrical Energy Systems (ICEES)\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 3rd International Conference on Electrical Energy Systems (ICEES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEES.2016.7510651\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 3rd International Conference on Electrical Energy Systems (ICEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEES.2016.7510651","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

电力需求的增加和发电量的不足导致了频繁的停电,这已经成为房主的主要担忧。由于光伏电池板价格的下降和对温室气体排放的担忧,铅酸基光伏系统在停电期间越来越受欢迎。用于储能的铅酸电池循环成本高,对环境影响大,处理不当会产生有害化合物污染环境。为了克服这一问题,本文提出了一种优化光伏电池尺寸的方法来减小屋顶光伏系统的电池尺寸,并采用合适的电池技术来降低系统的总拥有成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Li-ion based optimally sized grid interfaced roof top PV system
Increase in power demand and insufficient power generation has lead to frequent power cuts, which have become a major concern for house owners. Due to falling PV panel prices and concerns over greenhouse gas emissions, lead acid based PV systems are gaining popularity for home electrification during power cuts. Lead acid battery used for energy storage has high recurring cost and adversely impact the environment, with hazardous compounds contaminating the environment on its improper disposal. To overcome this issue, an optimal method of PV sizing is implemented in this paper to reduce battery sizing in roof top PV systems and a suitable battery technology is adopted to reduce the total cost of ownership of the system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信