Anggakara Syahbi Syagata, I. Setiawan, T. Andromeda, Hermawan, I. Sumpono, A. R. Mat Sidek
{"title":"使用PS-3005D直流电源快速充电LTO 18650电池","authors":"Anggakara Syahbi Syagata, I. Setiawan, T. Andromeda, Hermawan, I. Sumpono, A. R. Mat Sidek","doi":"10.1109/ICITACEE.2019.8904099","DOIUrl":null,"url":null,"abstract":"Recently, the adoption of LTO batteries as a solution to store energy and other utilisations has been widely prominent among various industries; such as automotive and telecommunication. As the adoption rate is increasing, it will be necessary to test LTO batteries to understand the fast-charging duration of LTO batteries. This research was conducted by arranging five LTO batteries in a series circuit to generate a 12 V voltage. A PS-3005D Zhaoxin with 5 A of current and 30 V of voltage was used as the power supply. This power supply would then supply currents gradually from 1 A to 3 A to the batteries. At the end of the test, the PS-3005D Zhaoxin power supply with 3 A or 2 C magnitude of current was able to fast-charge the 18650 LTO batteries in seven minutes. This test result demonstrates that using Zhaoxin PS-3005D as the power supply can reduce the fast-charging duration.","PeriodicalId":319683,"journal":{"name":"2019 6th International Conference on Information Technology, Computer and Electrical Engineering (ICITACEE)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fast-Charging LTO 18650 Batteries Using a DC PS-3005D Power Supply\",\"authors\":\"Anggakara Syahbi Syagata, I. Setiawan, T. Andromeda, Hermawan, I. Sumpono, A. R. Mat Sidek\",\"doi\":\"10.1109/ICITACEE.2019.8904099\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, the adoption of LTO batteries as a solution to store energy and other utilisations has been widely prominent among various industries; such as automotive and telecommunication. As the adoption rate is increasing, it will be necessary to test LTO batteries to understand the fast-charging duration of LTO batteries. This research was conducted by arranging five LTO batteries in a series circuit to generate a 12 V voltage. A PS-3005D Zhaoxin with 5 A of current and 30 V of voltage was used as the power supply. This power supply would then supply currents gradually from 1 A to 3 A to the batteries. At the end of the test, the PS-3005D Zhaoxin power supply with 3 A or 2 C magnitude of current was able to fast-charge the 18650 LTO batteries in seven minutes. This test result demonstrates that using Zhaoxin PS-3005D as the power supply can reduce the fast-charging duration.\",\"PeriodicalId\":319683,\"journal\":{\"name\":\"2019 6th International Conference on Information Technology, Computer and Electrical Engineering (ICITACEE)\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 6th International Conference on Information Technology, Computer and Electrical Engineering (ICITACEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICITACEE.2019.8904099\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 6th International Conference on Information Technology, Computer and Electrical Engineering (ICITACEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICITACEE.2019.8904099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fast-Charging LTO 18650 Batteries Using a DC PS-3005D Power Supply
Recently, the adoption of LTO batteries as a solution to store energy and other utilisations has been widely prominent among various industries; such as automotive and telecommunication. As the adoption rate is increasing, it will be necessary to test LTO batteries to understand the fast-charging duration of LTO batteries. This research was conducted by arranging five LTO batteries in a series circuit to generate a 12 V voltage. A PS-3005D Zhaoxin with 5 A of current and 30 V of voltage was used as the power supply. This power supply would then supply currents gradually from 1 A to 3 A to the batteries. At the end of the test, the PS-3005D Zhaoxin power supply with 3 A or 2 C magnitude of current was able to fast-charge the 18650 LTO batteries in seven minutes. This test result demonstrates that using Zhaoxin PS-3005D as the power supply can reduce the fast-charging duration.