Ziegler-Nichols PID整定法在热水机温度稳定中的实现

Ratna Aisuwarya, Y. Hidayati
{"title":"Ziegler-Nichols PID整定法在热水机温度稳定中的实现","authors":"Ratna Aisuwarya, Y. Hidayati","doi":"10.1109/QIR.2019.8898259","DOIUrl":null,"url":null,"abstract":"The low-cost dispenser has disadvantages such as unable to maintain the water temperature to remain stable. To brew hot drinks such as coffee and tea require a specific range of temperature of 90 – 96 °C. Several previous studies regarding automatic dispensers have discussed the existing problems; only there are still some drawbacks when controlling the temperature stability in the dispenser. Further development is needed to overcome these shortcomings. For that purpose, we proposed a dispenser that can maintain the stability of hot water temperature. This dispenser will make it easier for users to brew coffee and tea with the ideal water temperature and produce a stable temperature that produces a good quality drink. The designed system uses water-resistant temperature sensor. Voltage control is applied to the heating element using the Ziegler-Nichols PID Tuning Method in order to control the temperature stability. Experimental results show that the system can maintain the temperature of hot water in the dispenser to keep it stable with a range from 92.31 °C to 92.62 °C, while the system without controller unable to maintain the stability of hot water temperature because the hot water temperature reaches a maximum temperature of 95.62 °C exceeding the setpoint of 92 °C.","PeriodicalId":284463,"journal":{"name":"2019 16th International Conference on Quality in Research (QIR): International Symposium on Electrical and Computer Engineering","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Implementation of Ziegler-Nichols PID Tuning Method on Stabilizing Temperature of Hot-water Dispenser\",\"authors\":\"Ratna Aisuwarya, Y. Hidayati\",\"doi\":\"10.1109/QIR.2019.8898259\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The low-cost dispenser has disadvantages such as unable to maintain the water temperature to remain stable. To brew hot drinks such as coffee and tea require a specific range of temperature of 90 – 96 °C. Several previous studies regarding automatic dispensers have discussed the existing problems; only there are still some drawbacks when controlling the temperature stability in the dispenser. Further development is needed to overcome these shortcomings. For that purpose, we proposed a dispenser that can maintain the stability of hot water temperature. This dispenser will make it easier for users to brew coffee and tea with the ideal water temperature and produce a stable temperature that produces a good quality drink. The designed system uses water-resistant temperature sensor. Voltage control is applied to the heating element using the Ziegler-Nichols PID Tuning Method in order to control the temperature stability. Experimental results show that the system can maintain the temperature of hot water in the dispenser to keep it stable with a range from 92.31 °C to 92.62 °C, while the system without controller unable to maintain the stability of hot water temperature because the hot water temperature reaches a maximum temperature of 95.62 °C exceeding the setpoint of 92 °C.\",\"PeriodicalId\":284463,\"journal\":{\"name\":\"2019 16th International Conference on Quality in Research (QIR): International Symposium on Electrical and Computer Engineering\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 16th International Conference on Quality in Research (QIR): International Symposium on Electrical and Computer Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/QIR.2019.8898259\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 16th International Conference on Quality in Research (QIR): International Symposium on Electrical and Computer Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/QIR.2019.8898259","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

低成本的分配器有无法维持水温保持稳定等缺点。冲泡咖啡和茶等热饮需要90 - 96°C的特定温度范围。以前的一些关于自动点胶机的研究讨论了存在的问题;只是在控制点胶机的温度稳定性方面还有一些缺点。需要进一步的发展来克服这些缺点。为此,我们提出了一种能够保持热水温度稳定的饮水机。该饮水机将使用户更容易冲泡咖啡和茶,以理想的水温,并产生稳定的温度,生产出优质的饮料。设计的系统采用防水温度传感器。采用齐格勒-尼科尔斯PID整定方法对加热元件进行电压控制,以控制温度的稳定性。实验结果表明,该系统能够保持热水在点水壶内的温度在92.31℃~ 92.62℃范围内保持稳定,而没有控制器的系统无法保持热水温度的稳定,因为热水温度最高达到95.62℃,超过了设定点92℃。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Implementation of Ziegler-Nichols PID Tuning Method on Stabilizing Temperature of Hot-water Dispenser
The low-cost dispenser has disadvantages such as unable to maintain the water temperature to remain stable. To brew hot drinks such as coffee and tea require a specific range of temperature of 90 – 96 °C. Several previous studies regarding automatic dispensers have discussed the existing problems; only there are still some drawbacks when controlling the temperature stability in the dispenser. Further development is needed to overcome these shortcomings. For that purpose, we proposed a dispenser that can maintain the stability of hot water temperature. This dispenser will make it easier for users to brew coffee and tea with the ideal water temperature and produce a stable temperature that produces a good quality drink. The designed system uses water-resistant temperature sensor. Voltage control is applied to the heating element using the Ziegler-Nichols PID Tuning Method in order to control the temperature stability. Experimental results show that the system can maintain the temperature of hot water in the dispenser to keep it stable with a range from 92.31 °C to 92.62 °C, while the system without controller unable to maintain the stability of hot water temperature because the hot water temperature reaches a maximum temperature of 95.62 °C exceeding the setpoint of 92 °C.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信