V. Vaks, V.M. Daniltsev, A. Maslovsky, A.V. Murel, O. Khrykin, Y. Chechenin, V. Shashkin
{"title":"用于测量毫米波长范围内二极管探测器参数的自动化系统","authors":"V. Vaks, V.M. Daniltsev, A. Maslovsky, A.V. Murel, O. Khrykin, Y. Chechenin, V. Shashkin","doi":"10.1109/CRMICO.2001.961683","DOIUrl":null,"url":null,"abstract":"An automated system for measurement of the basic electrical parameters of waveguide detectors for the 2.4-3 mm wavelength range over a wide range of diode currents and the input radiation power is described. The measured parameters of low-barrier diodes created on the basis of application of delta InGaAs-GaAs are given as an example.","PeriodicalId":197471,"journal":{"name":"11th International Conference 'Microwave and Telecommunication Technology'. Conference Proceedings (IEEE Cat. No.01EX487)","volume":"233 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Automated system for the measurement of diode detector parameters in millimetre wavelength range\",\"authors\":\"V. Vaks, V.M. Daniltsev, A. Maslovsky, A.V. Murel, O. Khrykin, Y. Chechenin, V. Shashkin\",\"doi\":\"10.1109/CRMICO.2001.961683\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An automated system for measurement of the basic electrical parameters of waveguide detectors for the 2.4-3 mm wavelength range over a wide range of diode currents and the input radiation power is described. The measured parameters of low-barrier diodes created on the basis of application of delta InGaAs-GaAs are given as an example.\",\"PeriodicalId\":197471,\"journal\":{\"name\":\"11th International Conference 'Microwave and Telecommunication Technology'. Conference Proceedings (IEEE Cat. No.01EX487)\",\"volume\":\"233 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"11th International Conference 'Microwave and Telecommunication Technology'. Conference Proceedings (IEEE Cat. No.01EX487)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CRMICO.2001.961683\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"11th International Conference 'Microwave and Telecommunication Technology'. Conference Proceedings (IEEE Cat. No.01EX487)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CRMICO.2001.961683","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Automated system for the measurement of diode detector parameters in millimetre wavelength range
An automated system for measurement of the basic electrical parameters of waveguide detectors for the 2.4-3 mm wavelength range over a wide range of diode currents and the input radiation power is described. The measured parameters of low-barrier diodes created on the basis of application of delta InGaAs-GaAs are given as an example.