阵列光电脉搏波仪本质的新认识

Wei-Ru Han, Yang Ming Chou, Chih-Yuan Chuang, Chung-yuo Wu, Sen H. Huang
{"title":"阵列光电脉搏波仪本质的新认识","authors":"Wei-Ru Han, Yang Ming Chou, Chih-Yuan Chuang, Chung-yuo Wu, Sen H. Huang","doi":"10.1145/3326172.3326187","DOIUrl":null,"url":null,"abstract":"Photoplethysmography (PPG) has been widely used to investigate various cardiovascular conditions. Previous studies have demonstrated the effects of temperature of the measurement environment. However, an integrated evaluation has not been established in environments with gradual air temperature variations. This study was conducted to determine the correlation between the activity frequency (AF) of array PPG image and the changes in skin surface temperature (SST) by environment temperature control. The study participants were 13 company employees aged between 27 and 48 years (mean age: 35.6 years) who were treated with an IR heater to increase the skin temperature for approximately 15 min. Measurements of finger array PPG and finger SST were obtained before infrared heating as baseline, and the intervention of 15-min infrared heating was continued in the left hand as the experiment group. The right hand was not subjected to heating, which served as the control group. The results showed that the local fingertip SST increase affected the local AF of the array PPG image, which could be related to the biphasic skin blood flow response. The array PPG image could be used for monitoring the activity control of microcirculation or endothelial function.","PeriodicalId":293245,"journal":{"name":"Proceedings of the 2019 9th International Conference on Biomedical Engineering and Technology - ICBET' 19","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A New Look at the Essence of the Array Photoplethysmograph\",\"authors\":\"Wei-Ru Han, Yang Ming Chou, Chih-Yuan Chuang, Chung-yuo Wu, Sen H. Huang\",\"doi\":\"10.1145/3326172.3326187\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Photoplethysmography (PPG) has been widely used to investigate various cardiovascular conditions. Previous studies have demonstrated the effects of temperature of the measurement environment. However, an integrated evaluation has not been established in environments with gradual air temperature variations. This study was conducted to determine the correlation between the activity frequency (AF) of array PPG image and the changes in skin surface temperature (SST) by environment temperature control. The study participants were 13 company employees aged between 27 and 48 years (mean age: 35.6 years) who were treated with an IR heater to increase the skin temperature for approximately 15 min. Measurements of finger array PPG and finger SST were obtained before infrared heating as baseline, and the intervention of 15-min infrared heating was continued in the left hand as the experiment group. The right hand was not subjected to heating, which served as the control group. The results showed that the local fingertip SST increase affected the local AF of the array PPG image, which could be related to the biphasic skin blood flow response. The array PPG image could be used for monitoring the activity control of microcirculation or endothelial function.\",\"PeriodicalId\":293245,\"journal\":{\"name\":\"Proceedings of the 2019 9th International Conference on Biomedical Engineering and Technology - ICBET' 19\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2019 9th International Conference on Biomedical Engineering and Technology - ICBET' 19\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3326172.3326187\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2019 9th International Conference on Biomedical Engineering and Technology - ICBET' 19","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3326172.3326187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

光容积脉搏波(PPG)已被广泛应用于各种心血管疾病的研究。以前的研究已经证明了测量环境温度的影响。然而,在气温逐渐变化的环境中尚未建立综合评价。本研究通过环境温度控制,确定阵列PPG图像的活动频率(AF)与皮肤表面温度(SST)变化的相关性。研究对象为13名年龄在27 - 48岁之间(平均年龄35.6岁)的公司员工,他们用红外加热器升高皮肤温度约15分钟。在红外加热前测量手指阵列PPG和手指SST作为基线,左手作为实验组继续进行15分钟的红外加热干预。右手不进行加热,作为对照组。结果表明,指尖局部SST升高影响阵列PPG图像的局部AF,这可能与双相皮肤血流反应有关。阵列PPG图像可用于监测微循环或内皮功能的活性控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A New Look at the Essence of the Array Photoplethysmograph
Photoplethysmography (PPG) has been widely used to investigate various cardiovascular conditions. Previous studies have demonstrated the effects of temperature of the measurement environment. However, an integrated evaluation has not been established in environments with gradual air temperature variations. This study was conducted to determine the correlation between the activity frequency (AF) of array PPG image and the changes in skin surface temperature (SST) by environment temperature control. The study participants were 13 company employees aged between 27 and 48 years (mean age: 35.6 years) who were treated with an IR heater to increase the skin temperature for approximately 15 min. Measurements of finger array PPG and finger SST were obtained before infrared heating as baseline, and the intervention of 15-min infrared heating was continued in the left hand as the experiment group. The right hand was not subjected to heating, which served as the control group. The results showed that the local fingertip SST increase affected the local AF of the array PPG image, which could be related to the biphasic skin blood flow response. The array PPG image could be used for monitoring the activity control of microcirculation or endothelial function.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信