复合纤维桩与常规纤维桩的体外结合比较研究

Prakash Nidawan, Shiva Sai Vemula, Saumya Singh, Girish Galagali, Ameer Khan Pattan
{"title":"复合纤维桩与常规纤维桩的体外结合比较研究","authors":"Prakash Nidawan, Shiva Sai Vemula, Saumya Singh, Girish Galagali, Ameer Khan Pattan","doi":"10.37983/ijdm.2023.5201","DOIUrl":null,"url":null,"abstract":"Background:Fiber posts are widely used aesthetic material in restorative dentistry. These materials were introduced to overcome the inherent shortcomings of cast posts.Aim: This study aimed to evaluate and compare the pull-out bond strengthof fibre posts with relining and without relining.Materials and methods:Twenty maxillary canines were extracted and underwent endodontic treatment, involving the removal of their crown portion. Post-space preparation was performed, and the appropriate post size was selected. In Group 1, ten samples were coated with a layer of composite, reinserted into the post space of the canal, and then light cured outside the canal. The other ten samples (Group 2) were without relining. The fibre posts from both groups were cemented with RMGIC. The samples were mounted in tensile fixtures ofthe universal testing machine and subjected to a tensile load until the posts were debonded. The debonded samples were analysed using a stereo microscope for bond failure analysis. The obtained results were subjected to statistical analysis.Results:The mean pull-out force in group 1 and group 2 was 72.2100±8.56420 and 61.3700±11.00611, respectively. One way ANOVA analysis showed a significant difference in the pull-out force among the groups (P=0.043). In Group 1, 30% of the samples reported adhesive-2failures and 70% adhesive-1&2 failures. But in Group 2, all samples were reported with adhesive-3 failures. Fisher’s Exact test displayed a significant difference in the type of bond failure between the groups (P=0.003).Conclusions:This study concluded that the coating of the fibre posts improves their tensile strength.","PeriodicalId":132317,"journal":{"name":"International Journal of Dental Materials","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative evaluation of bondingbetween composite relined fibre post and Conventional fibre post: an in-vitrostudy\",\"authors\":\"Prakash Nidawan, Shiva Sai Vemula, Saumya Singh, Girish Galagali, Ameer Khan Pattan\",\"doi\":\"10.37983/ijdm.2023.5201\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background:Fiber posts are widely used aesthetic material in restorative dentistry. These materials were introduced to overcome the inherent shortcomings of cast posts.Aim: This study aimed to evaluate and compare the pull-out bond strengthof fibre posts with relining and without relining.Materials and methods:Twenty maxillary canines were extracted and underwent endodontic treatment, involving the removal of their crown portion. Post-space preparation was performed, and the appropriate post size was selected. In Group 1, ten samples were coated with a layer of composite, reinserted into the post space of the canal, and then light cured outside the canal. The other ten samples (Group 2) were without relining. The fibre posts from both groups were cemented with RMGIC. The samples were mounted in tensile fixtures ofthe universal testing machine and subjected to a tensile load until the posts were debonded. The debonded samples were analysed using a stereo microscope for bond failure analysis. The obtained results were subjected to statistical analysis.Results:The mean pull-out force in group 1 and group 2 was 72.2100±8.56420 and 61.3700±11.00611, respectively. One way ANOVA analysis showed a significant difference in the pull-out force among the groups (P=0.043). In Group 1, 30% of the samples reported adhesive-2failures and 70% adhesive-1&2 failures. But in Group 2, all samples were reported with adhesive-3 failures. Fisher’s Exact test displayed a significant difference in the type of bond failure between the groups (P=0.003).Conclusions:This study concluded that the coating of the fibre posts improves their tensile strength.\",\"PeriodicalId\":132317,\"journal\":{\"name\":\"International Journal of Dental Materials\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Dental Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37983/ijdm.2023.5201\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Dental Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37983/ijdm.2023.5201","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:纤维桩是牙科修复中广泛使用的美学材料。引入这些材料是为了克服铸柱的固有缺点。目的:评价和比较纤维桩加衬和不加衬的拉拔结合强度。材料和方法:拔除20只上颌犬,进行牙髓治疗,包括去除牙冠部分。进行岗位空间准备,选择合适的岗位规模。在第1组,10个样品涂上一层复合材料,重新插入根管的桩空间,然后在根管外光固化。另外10个样本(第二组)未进行复配。两组纤维桩均用RMGIC粘接。将样品安装在万能试验机的拉伸夹具上,并承受拉伸载荷,直到立柱脱落。用立体显微镜对脱粘试样进行粘接失效分析。所得结果进行了统计分析。结果:1、2组平均拔牙力分别为72.2100±8.56420、61.3700±11.00611。单因素方差分析显示,两组间拔牙力差异有统计学意义(P=0.043)。在第1组中,30%的样品报告了粘合剂2失效,70%的样品报告了粘合剂1和2失效。但在第二组中,所有样品都报告了粘合剂-3失效。Fisher’s Exact检验显示,两组间的bond failure类型有显著差异(P=0.003)。结论:纤维桩的涂层可以提高纤维桩的抗拉强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative evaluation of bondingbetween composite relined fibre post and Conventional fibre post: an in-vitrostudy
Background:Fiber posts are widely used aesthetic material in restorative dentistry. These materials were introduced to overcome the inherent shortcomings of cast posts.Aim: This study aimed to evaluate and compare the pull-out bond strengthof fibre posts with relining and without relining.Materials and methods:Twenty maxillary canines were extracted and underwent endodontic treatment, involving the removal of their crown portion. Post-space preparation was performed, and the appropriate post size was selected. In Group 1, ten samples were coated with a layer of composite, reinserted into the post space of the canal, and then light cured outside the canal. The other ten samples (Group 2) were without relining. The fibre posts from both groups were cemented with RMGIC. The samples were mounted in tensile fixtures ofthe universal testing machine and subjected to a tensile load until the posts were debonded. The debonded samples were analysed using a stereo microscope for bond failure analysis. The obtained results were subjected to statistical analysis.Results:The mean pull-out force in group 1 and group 2 was 72.2100±8.56420 and 61.3700±11.00611, respectively. One way ANOVA analysis showed a significant difference in the pull-out force among the groups (P=0.043). In Group 1, 30% of the samples reported adhesive-2failures and 70% adhesive-1&2 failures. But in Group 2, all samples were reported with adhesive-3 failures. Fisher’s Exact test displayed a significant difference in the type of bond failure between the groups (P=0.003).Conclusions:This study concluded that the coating of the fibre posts improves their tensile strength.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信