通过a扫描的超宽带物体表征

G. Oßberger, T. Buchegger, K. Pourvoyeur, E. Schimback, A. Stelzer, R. Weigel
{"title":"通过a扫描的超宽带物体表征","authors":"G. Oßberger, T. Buchegger, K. Pourvoyeur, E. Schimback, A. Stelzer, R. Weigel","doi":"10.1109/UWBST.2003.1267888","DOIUrl":null,"url":null,"abstract":"In this paper a novel method for ultra-wideband object characterization using a single A-scan is presented. The impulse response of the arrangement at a single measurement position is called an A-scan. The data of an A-scan is processed with the novel wavelet based pulse reconstruction to determine five parameters of the pulse approximation. The width of different copper plates can be characterized by the dilatation of the reconstructed pulse which is one of the five parameters. To get real radar reflection data an ultra-wideband impulse radar setup was used. The presented results testify, that there is a direct link between the parameter dilatation factor and the width of a centered copper plate. To verify the results of the measurement analysis a simulation tool was developed. The presented results of the simulation accord very good with the measurement.","PeriodicalId":218975,"journal":{"name":"IEEE Conference on Ultra Wideband Systems and Technologies, 2003","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Ultra-wideband object characterization via A-scan\",\"authors\":\"G. Oßberger, T. Buchegger, K. Pourvoyeur, E. Schimback, A. Stelzer, R. Weigel\",\"doi\":\"10.1109/UWBST.2003.1267888\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a novel method for ultra-wideband object characterization using a single A-scan is presented. The impulse response of the arrangement at a single measurement position is called an A-scan. The data of an A-scan is processed with the novel wavelet based pulse reconstruction to determine five parameters of the pulse approximation. The width of different copper plates can be characterized by the dilatation of the reconstructed pulse which is one of the five parameters. To get real radar reflection data an ultra-wideband impulse radar setup was used. The presented results testify, that there is a direct link between the parameter dilatation factor and the width of a centered copper plate. To verify the results of the measurement analysis a simulation tool was developed. The presented results of the simulation accord very good with the measurement.\",\"PeriodicalId\":218975,\"journal\":{\"name\":\"IEEE Conference on Ultra Wideband Systems and Technologies, 2003\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-11-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Conference on Ultra Wideband Systems and Technologies, 2003\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UWBST.2003.1267888\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Conference on Ultra Wideband Systems and Technologies, 2003","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UWBST.2003.1267888","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了一种利用单次a扫描进行超宽带目标表征的新方法。排列在单个测量位置的脉冲响应称为a扫描。采用基于小波变换的脉冲重构方法对a扫描数据进行处理,确定了脉冲近似的5个参数。不同铜板的宽度可以通过重建脉冲的扩张来表征,这是五个参数之一。为了获得真实的雷达反射数据,采用了超宽带脉冲雷达装置。结果表明,膨胀系数与中心铜板的宽度有直接的关系。为了验证测量分析的结果,开发了仿真工具。仿真结果与实测结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ultra-wideband object characterization via A-scan
In this paper a novel method for ultra-wideband object characterization using a single A-scan is presented. The impulse response of the arrangement at a single measurement position is called an A-scan. The data of an A-scan is processed with the novel wavelet based pulse reconstruction to determine five parameters of the pulse approximation. The width of different copper plates can be characterized by the dilatation of the reconstructed pulse which is one of the five parameters. To get real radar reflection data an ultra-wideband impulse radar setup was used. The presented results testify, that there is a direct link between the parameter dilatation factor and the width of a centered copper plate. To verify the results of the measurement analysis a simulation tool was developed. The presented results of the simulation accord very good with the measurement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信