变电站配电变压器热模型的模型筛选方法

Shruti Rao, Ming Zhang, D. Tylavsky
{"title":"变电站配电变压器热模型的模型筛选方法","authors":"Shruti Rao, Ming Zhang, D. Tylavsky","doi":"10.1109/NAPS.2013.6666841","DOIUrl":null,"url":null,"abstract":"Dynamic loading of transformers is the term used when the loading capacity is calculated using an appropriate thermal model while taking into account the load magnitude, load shape, thermal limits and external cooling conditions. For transformer dynamic loading, the aim is to estimate the transformer's maximum dynamic loading capacity without violating the hottest-spot temperature (HST) and top-oil temperature (TOT) thermal limits. These two temperatures are proxy measures of insulation temperature, which can be used to estimate the loss of service life. The accuracy of the TOT and HST predictions is dependent on many things, central to which is the accuracy of the thermal model. This paper introduces metrics that can be used to differentiate between reliable and unreliable transformer thermal models. The two models discussed in this paper for HST and TOT are the non-linear IEEE model and the model developed by the authors using linear regression methods.","PeriodicalId":421943,"journal":{"name":"2013 North American Power Symposium (NAPS)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Model screening metrics for thermal models of substation distribution transformers\",\"authors\":\"Shruti Rao, Ming Zhang, D. Tylavsky\",\"doi\":\"10.1109/NAPS.2013.6666841\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Dynamic loading of transformers is the term used when the loading capacity is calculated using an appropriate thermal model while taking into account the load magnitude, load shape, thermal limits and external cooling conditions. For transformer dynamic loading, the aim is to estimate the transformer's maximum dynamic loading capacity without violating the hottest-spot temperature (HST) and top-oil temperature (TOT) thermal limits. These two temperatures are proxy measures of insulation temperature, which can be used to estimate the loss of service life. The accuracy of the TOT and HST predictions is dependent on many things, central to which is the accuracy of the thermal model. This paper introduces metrics that can be used to differentiate between reliable and unreliable transformer thermal models. The two models discussed in this paper for HST and TOT are the non-linear IEEE model and the model developed by the authors using linear regression methods.\",\"PeriodicalId\":421943,\"journal\":{\"name\":\"2013 North American Power Symposium (NAPS)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 North American Power Symposium (NAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2013.6666841\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2013.6666841","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

变压器的动态负荷是指在考虑负荷大小、负荷形状、热极限和外部冷却条件的情况下,采用适当的热模型计算负载能力的术语。变压器动态负荷的目的是在不超出热点温度和顶油温度极限的情况下估计变压器的最大动态负荷能力。这两个温度是绝缘温度的替代测量,可以用来估计使用寿命的损失。TOT和HST预测的准确性取决于许多因素,其中最重要的是热模型的准确性。本文介绍了可用于区分可靠和不可靠变压器热模型的指标。本文讨论的两种HST和TOT模型分别是非线性IEEE模型和作者利用线性回归方法建立的模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Model screening metrics for thermal models of substation distribution transformers
Dynamic loading of transformers is the term used when the loading capacity is calculated using an appropriate thermal model while taking into account the load magnitude, load shape, thermal limits and external cooling conditions. For transformer dynamic loading, the aim is to estimate the transformer's maximum dynamic loading capacity without violating the hottest-spot temperature (HST) and top-oil temperature (TOT) thermal limits. These two temperatures are proxy measures of insulation temperature, which can be used to estimate the loss of service life. The accuracy of the TOT and HST predictions is dependent on many things, central to which is the accuracy of the thermal model. This paper introduces metrics that can be used to differentiate between reliable and unreliable transformer thermal models. The two models discussed in this paper for HST and TOT are the non-linear IEEE model and the model developed by the authors using linear regression methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信