E. Piuzzi, A. Capuano, S. Pisa, P. Cappa, F. Patané, S. Rossi, N. Giaquinto, G. M. D'Aucelli
{"title":"用于减少运动伪影的带有惯性测量单元的阻抗容积描记系统:用于连续呼吸活动监测","authors":"E. Piuzzi, A. Capuano, S. Pisa, P. Cappa, F. Patané, S. Rossi, N. Giaquinto, G. M. D'Aucelli","doi":"10.1109/MeMeA.2015.7145233","DOIUrl":null,"url":null,"abstract":"This paper presents an impedance plethysmography system suitable to perform a continuous monitoring of human breath activity. The problem of motion artifact is mitigated through the use of a correction technique exploiting an additional inertial sensor able to detect movements of the arms of the subject under test. The correction algorithm is based on a simple correlation technique and only requires a very brief training at the beginning of the acquisition session, with the monitored subject performing random movements in apnea condition. Application of the proposed system to a healthy adult volunteer demonstrates the potentiality of the correction algorithm, which, thanks to its extreme simplicity and low computational cost, is a suitable candidate for implementation in a low-cost and portable monitoring system.","PeriodicalId":277757,"journal":{"name":"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings","volume":"388 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Impedance plethysmography system with inertial measurement units for motion artefact reduction: Application to continuous breath activity monitoring\",\"authors\":\"E. Piuzzi, A. Capuano, S. Pisa, P. Cappa, F. Patané, S. Rossi, N. Giaquinto, G. M. D'Aucelli\",\"doi\":\"10.1109/MeMeA.2015.7145233\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an impedance plethysmography system suitable to perform a continuous monitoring of human breath activity. The problem of motion artifact is mitigated through the use of a correction technique exploiting an additional inertial sensor able to detect movements of the arms of the subject under test. The correction algorithm is based on a simple correlation technique and only requires a very brief training at the beginning of the acquisition session, with the monitored subject performing random movements in apnea condition. Application of the proposed system to a healthy adult volunteer demonstrates the potentiality of the correction algorithm, which, thanks to its extreme simplicity and low computational cost, is a suitable candidate for implementation in a low-cost and portable monitoring system.\",\"PeriodicalId\":277757,\"journal\":{\"name\":\"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings\",\"volume\":\"388 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA.2015.7145233\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2015.7145233","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Impedance plethysmography system with inertial measurement units for motion artefact reduction: Application to continuous breath activity monitoring
This paper presents an impedance plethysmography system suitable to perform a continuous monitoring of human breath activity. The problem of motion artifact is mitigated through the use of a correction technique exploiting an additional inertial sensor able to detect movements of the arms of the subject under test. The correction algorithm is based on a simple correlation technique and only requires a very brief training at the beginning of the acquisition session, with the monitored subject performing random movements in apnea condition. Application of the proposed system to a healthy adult volunteer demonstrates the potentiality of the correction algorithm, which, thanks to its extreme simplicity and low computational cost, is a suitable candidate for implementation in a low-cost and portable monitoring system.