{"title":"一种新型下肢外部机械压缩系统实现降噪","authors":"K. Giuliano, Rachel A. Pozzar","doi":"10.1177/10648046211016690","DOIUrl":null,"url":null,"abstract":"Hospitals are one of the noisiest public environments in the United States, and hospital noise is associated with disrupted sleep. This study provides insights into the noise levels produced by three commonly used medical devices for mechanical deep vein thrombosis prophylaxis: the VenaFlow Elite System, the Kendall SCD Compression System, and the ArjoHuntleigh Flowtron. Noise levels produced were compared with a novel device, the RF Health MAC™ system, which was designed to provide improved comfort and noise reduction. Results suggest that future innovation in mechanical deep vein thrombosis prophylaxis should include efforts to reduce noise during operation.","PeriodicalId":357563,"journal":{"name":"Ergonomics in Design: The Quarterly of Human Factors Applications","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Achieving Noise Reduction With a Novel Lower Limb External Mechanical Compression System\",\"authors\":\"K. Giuliano, Rachel A. Pozzar\",\"doi\":\"10.1177/10648046211016690\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Hospitals are one of the noisiest public environments in the United States, and hospital noise is associated with disrupted sleep. This study provides insights into the noise levels produced by three commonly used medical devices for mechanical deep vein thrombosis prophylaxis: the VenaFlow Elite System, the Kendall SCD Compression System, and the ArjoHuntleigh Flowtron. Noise levels produced were compared with a novel device, the RF Health MAC™ system, which was designed to provide improved comfort and noise reduction. Results suggest that future innovation in mechanical deep vein thrombosis prophylaxis should include efforts to reduce noise during operation.\",\"PeriodicalId\":357563,\"journal\":{\"name\":\"Ergonomics in Design: The Quarterly of Human Factors Applications\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ergonomics in Design: The Quarterly of Human Factors Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/10648046211016690\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ergonomics in Design: The Quarterly of Human Factors Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/10648046211016690","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
医院是美国最嘈杂的公共环境之一,医院的噪音与睡眠中断有关。这项研究提供了三种常用的机械深静脉血栓预防医疗设备产生的噪音水平的见解:VenaFlow Elite系统,Kendall SCD压缩系统和ArjoHuntleigh Flowtron。产生的噪声水平与一种新型设备RF Health MAC™系统进行了比较,该系统旨在提供更好的舒适性和降噪效果。结果表明,未来机械预防深静脉血栓形成的创新应包括努力减少手术过程中的噪音。
Achieving Noise Reduction With a Novel Lower Limb External Mechanical Compression System
Hospitals are one of the noisiest public environments in the United States, and hospital noise is associated with disrupted sleep. This study provides insights into the noise levels produced by three commonly used medical devices for mechanical deep vein thrombosis prophylaxis: the VenaFlow Elite System, the Kendall SCD Compression System, and the ArjoHuntleigh Flowtron. Noise levels produced were compared with a novel device, the RF Health MAC™ system, which was designed to provide improved comfort and noise reduction. Results suggest that future innovation in mechanical deep vein thrombosis prophylaxis should include efforts to reduce noise during operation.