使用大猩猩部队优化器的定向过流继电器的最佳协调

Merabet Oussama, Bouchahdane Mohamed, Belmadani Hamza, Kheldoun Aissa, Eltom Ahmed, Bradai Rafik
{"title":"使用大猩猩部队优化器的定向过流继电器的最佳协调","authors":"Merabet Oussama, Bouchahdane Mohamed, Belmadani Hamza, Kheldoun Aissa, Eltom Ahmed, Bradai Rafik","doi":"10.1109/ICAECCS56710.2023.10105106","DOIUrl":null,"url":null,"abstract":"The optimization of coordination of directional overcurrent relays in an interconnected power system is given in this work. The goal of protective relay coordination is to achieve selectivity while maintaining sensitivity and a fast fault clearing time. The coordination research revolves around calculating the relays’ time dial setting (TDS) and plug setting (PS). DOCR coordination is a difficult and fascinating problem in nonlinear optimization. To avoid too much breakdown and interference, the overall working duration of all necessary relays must be kept to a minimum. To solve the coordination issue at the DOCR, coordination is carried out using the Gorilla troops optimizer (GTO). IEEE 3-bus and 8-bus test systems are among the test systems to which the suggested method has been implemented. The Results collected demonstrate the suggested GTO efficiency in reducing the relay operation time for the DOCRs’ optimum cooperation.","PeriodicalId":447668,"journal":{"name":"2023 International Conference on Advances in Electronics, Control and Communication Systems (ICAECCS)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An optimal coordination of directional overcurrent relays using a Gorilla troops optimizer\",\"authors\":\"Merabet Oussama, Bouchahdane Mohamed, Belmadani Hamza, Kheldoun Aissa, Eltom Ahmed, Bradai Rafik\",\"doi\":\"10.1109/ICAECCS56710.2023.10105106\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The optimization of coordination of directional overcurrent relays in an interconnected power system is given in this work. The goal of protective relay coordination is to achieve selectivity while maintaining sensitivity and a fast fault clearing time. The coordination research revolves around calculating the relays’ time dial setting (TDS) and plug setting (PS). DOCR coordination is a difficult and fascinating problem in nonlinear optimization. To avoid too much breakdown and interference, the overall working duration of all necessary relays must be kept to a minimum. To solve the coordination issue at the DOCR, coordination is carried out using the Gorilla troops optimizer (GTO). IEEE 3-bus and 8-bus test systems are among the test systems to which the suggested method has been implemented. The Results collected demonstrate the suggested GTO efficiency in reducing the relay operation time for the DOCRs’ optimum cooperation.\",\"PeriodicalId\":447668,\"journal\":{\"name\":\"2023 International Conference on Advances in Electronics, Control and Communication Systems (ICAECCS)\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 International Conference on Advances in Electronics, Control and Communication Systems (ICAECCS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAECCS56710.2023.10105106\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 International Conference on Advances in Electronics, Control and Communication Systems (ICAECCS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAECCS56710.2023.10105106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文研究了互联电力系统中定向过流继电器的协调优化问题。保护继电器协调的目标是在保持灵敏度和快速故障清除时间的同时实现选择性。协调研究围绕继电器时间拨盘整定(TDS)和插头整定(PS)的计算展开。DOCR协调是非线性优化中的一个难点和难点问题。为了避免过多的击穿和干扰,所有必要继电器的总工作时间必须保持在最低限度。为了解决DOCR的协调问题,使用大猩猩部队优化器(GTO)进行协调。IEEE 3总线和8总线测试系统是采用该方法的测试系统之一。研究结果表明,GTO在减少中继操作时间方面具有一定的效率,可促进多台网的最佳合作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An optimal coordination of directional overcurrent relays using a Gorilla troops optimizer
The optimization of coordination of directional overcurrent relays in an interconnected power system is given in this work. The goal of protective relay coordination is to achieve selectivity while maintaining sensitivity and a fast fault clearing time. The coordination research revolves around calculating the relays’ time dial setting (TDS) and plug setting (PS). DOCR coordination is a difficult and fascinating problem in nonlinear optimization. To avoid too much breakdown and interference, the overall working duration of all necessary relays must be kept to a minimum. To solve the coordination issue at the DOCR, coordination is carried out using the Gorilla troops optimizer (GTO). IEEE 3-bus and 8-bus test systems are among the test systems to which the suggested method has been implemented. The Results collected demonstrate the suggested GTO efficiency in reducing the relay operation time for the DOCRs’ optimum cooperation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信