{"title":"现场与实验室50公里超长铒光纤激光器的比较","authors":"L. Saito, E. A. de Souza, M. Romero","doi":"10.1109/LEOS.2009.5343334","DOIUrl":null,"url":null,"abstract":"We present a comparison between an in-held and an in-laboratory 50 km ultralong erbium-doped fiber lasers operating in active mode-locking regime. The results show better performance of the in-laboratory laser with pulses from 36.1 to 97.3 ps with repetition rate from 1 to 10 GHz.","PeriodicalId":269220,"journal":{"name":"2009 IEEE LEOS Annual Meeting Conference Proceedings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comparison between an in-field and an in-laboratory 50 km ultralong Erbium fiber laser\",\"authors\":\"L. Saito, E. A. de Souza, M. Romero\",\"doi\":\"10.1109/LEOS.2009.5343334\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present a comparison between an in-held and an in-laboratory 50 km ultralong erbium-doped fiber lasers operating in active mode-locking regime. The results show better performance of the in-laboratory laser with pulses from 36.1 to 97.3 ps with repetition rate from 1 to 10 GHz.\",\"PeriodicalId\":269220,\"journal\":{\"name\":\"2009 IEEE LEOS Annual Meeting Conference Proceedings\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE LEOS Annual Meeting Conference Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/LEOS.2009.5343334\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE LEOS Annual Meeting Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/LEOS.2009.5343334","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A comparison between an in-field and an in-laboratory 50 km ultralong Erbium fiber laser
We present a comparison between an in-held and an in-laboratory 50 km ultralong erbium-doped fiber lasers operating in active mode-locking regime. The results show better performance of the in-laboratory laser with pulses from 36.1 to 97.3 ps with repetition rate from 1 to 10 GHz.