用于饮用水处理的创新UV-C LED消毒系统

B. Vairamohan, G. Hunter, C. Arzbaecher, R. Ehrhard, J. Goodrich, John Hall
{"title":"用于饮用水处理的创新UV-C LED消毒系统","authors":"B. Vairamohan, G. Hunter, C. Arzbaecher, R. Ehrhard, J. Goodrich, John Hall","doi":"10.1109/SusTech51236.2021.9467430","DOIUrl":null,"url":null,"abstract":"This paper describes the testing of two UV-C LED water disinfection pilot-scale units at the U.S. Environmental Protection Agency (EPA) Test and Evaluation Facility in Cincinnati, OH from December 2018 to October 2019. The pilot-scale testing included collimated beam testing and flow-through testing for both drinking water and municipal wastewater. The challenge test runs targeted MS-2 bacteriophage, total coliforms, heterotrophic plate count (HPC), Bacillus globigii, and Legionella in drinking water, and E.coli, Enterococci, total coliforms, HPC, and Bacillus globigii in municipal wastewater. The paper presents the results for MS-2 bacteriophage, total coliforms and HPC in drinking water.","PeriodicalId":127126,"journal":{"name":"2021 IEEE Conference on Technologies for Sustainability (SusTech)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Innovative UV-C LED Disinfection Systems for DrinkingWater Treatment\",\"authors\":\"B. Vairamohan, G. Hunter, C. Arzbaecher, R. Ehrhard, J. Goodrich, John Hall\",\"doi\":\"10.1109/SusTech51236.2021.9467430\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the testing of two UV-C LED water disinfection pilot-scale units at the U.S. Environmental Protection Agency (EPA) Test and Evaluation Facility in Cincinnati, OH from December 2018 to October 2019. The pilot-scale testing included collimated beam testing and flow-through testing for both drinking water and municipal wastewater. The challenge test runs targeted MS-2 bacteriophage, total coliforms, heterotrophic plate count (HPC), Bacillus globigii, and Legionella in drinking water, and E.coli, Enterococci, total coliforms, HPC, and Bacillus globigii in municipal wastewater. The paper presents the results for MS-2 bacteriophage, total coliforms and HPC in drinking water.\",\"PeriodicalId\":127126,\"journal\":{\"name\":\"2021 IEEE Conference on Technologies for Sustainability (SusTech)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE Conference on Technologies for Sustainability (SusTech)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SusTech51236.2021.9467430\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Conference on Technologies for Sustainability (SusTech)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SusTech51236.2021.9467430","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文介绍了2018年12月至2019年10月在俄亥俄州辛辛那提市美国环境保护署(EPA)测试和评估设施对两台UV-C LED水消毒中试设备的测试情况。中试规模的测试包括准直光束测试和饮用水和城市污水的流量测试。挑战试验针对饮用水中的MS-2噬菌体、总大肠菌群、异养平板计数(HPC)、球状芽孢杆菌和军团菌,以及城市污水中的大肠杆菌、肠球菌、总大肠菌群、HPC和球状芽孢杆菌。本文介绍了饮用水中MS-2噬菌体、总大肠菌群和HPC的检测结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Innovative UV-C LED Disinfection Systems for DrinkingWater Treatment
This paper describes the testing of two UV-C LED water disinfection pilot-scale units at the U.S. Environmental Protection Agency (EPA) Test and Evaluation Facility in Cincinnati, OH from December 2018 to October 2019. The pilot-scale testing included collimated beam testing and flow-through testing for both drinking water and municipal wastewater. The challenge test runs targeted MS-2 bacteriophage, total coliforms, heterotrophic plate count (HPC), Bacillus globigii, and Legionella in drinking water, and E.coli, Enterococci, total coliforms, HPC, and Bacillus globigii in municipal wastewater. The paper presents the results for MS-2 bacteriophage, total coliforms and HPC in drinking water.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信