基于连续单周期的重采样数据拼接方法在电能质量分析中的应用

Siyang Deng, Zhu Liu, Lvchao Huang, Yonggui Wang, Kaiming Chen
{"title":"基于连续单周期的重采样数据拼接方法在电能质量分析中的应用","authors":"Siyang Deng, Zhu Liu, Lvchao Huang, Yonggui Wang, Kaiming Chen","doi":"10.1109/ICEI52466.2021.00015","DOIUrl":null,"url":null,"abstract":"When analyzing the spectrum of sampling data received from analog-to-digital converter, it usually could not satisfy the constraint that the length of the signal should be an integer power of 2 for FFT calculation. The common approach is to increase the sampling time or to fill the zeros after the signal, but these methods would cause the spectrum leakage or increase the time consuming for analysis. Therefore, this paper proposes an improved power quality data processing algorithm based on signal interpolation resample for continuous single cycle, and compares it with the common methods. The simulation results show that the improved algorithm can accurately capture the real frequency characteristics of the signal without increasing the signal sampling load or the amount of calculation.","PeriodicalId":113203,"journal":{"name":"2021 IEEE International Conference on Energy Internet (ICEI)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Resampled data splicing method based on continuous single-cycle used in power quality analysis\",\"authors\":\"Siyang Deng, Zhu Liu, Lvchao Huang, Yonggui Wang, Kaiming Chen\",\"doi\":\"10.1109/ICEI52466.2021.00015\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When analyzing the spectrum of sampling data received from analog-to-digital converter, it usually could not satisfy the constraint that the length of the signal should be an integer power of 2 for FFT calculation. The common approach is to increase the sampling time or to fill the zeros after the signal, but these methods would cause the spectrum leakage or increase the time consuming for analysis. Therefore, this paper proposes an improved power quality data processing algorithm based on signal interpolation resample for continuous single cycle, and compares it with the common methods. The simulation results show that the improved algorithm can accurately capture the real frequency characteristics of the signal without increasing the signal sampling load or the amount of calculation.\",\"PeriodicalId\":113203,\"journal\":{\"name\":\"2021 IEEE International Conference on Energy Internet (ICEI)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE International Conference on Energy Internet (ICEI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEI52466.2021.00015\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Conference on Energy Internet (ICEI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEI52466.2021.00015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在分析模数转换器接收到的采样数据的频谱时,通常不能满足FFT计算中信号长度必须为2的整数次幂的约束。常用的方法是增加采样时间或在信号后填充零点,但这些方法会造成频谱泄漏或增加分析时间。为此,本文提出了一种基于连续单周期信号插值采样的改进电能质量数据处理算法,并与常用方法进行了比较。仿真结果表明,改进后的算法在不增加信号采样负荷和计算量的情况下,能够准确捕捉信号的真实频率特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Resampled data splicing method based on continuous single-cycle used in power quality analysis
When analyzing the spectrum of sampling data received from analog-to-digital converter, it usually could not satisfy the constraint that the length of the signal should be an integer power of 2 for FFT calculation. The common approach is to increase the sampling time or to fill the zeros after the signal, but these methods would cause the spectrum leakage or increase the time consuming for analysis. Therefore, this paper proposes an improved power quality data processing algorithm based on signal interpolation resample for continuous single cycle, and compares it with the common methods. The simulation results show that the improved algorithm can accurately capture the real frequency characteristics of the signal without increasing the signal sampling load or the amount of calculation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信