Jiang Aipeng, Li Weiwei, Ding Qiang, Wang Jian, Jiang Zhou-shu, H. Guohui
{"title":"浆料流化床锅炉干法脱硫负荷坐标联合控制方法研究","authors":"Jiang Aipeng, Li Weiwei, Ding Qiang, Wang Jian, Jiang Zhou-shu, H. Guohui","doi":"10.1109/WCICA.2012.6359036","DOIUrl":null,"url":null,"abstract":"It is the most effective resource use practices for slurry and slime to be used as fuel for Fluidized bed boiler. The dry desulfurization of sludge Fluidized bed boiler is a large time delay system, and load disturbance of this system changes frequently. In order to achieve stable control of SO2 emission, and meet environmental requirements, a fuzzy control technology combined with the optimal feed-forward was designed. Combined with field experience, fuzzy controller was designed by fuzzy control technology, and then the integral process was added to achieve non-error track. Based on the objective to minimize disturbance impact, and in order to coordinate the desulfurization control and steam load control, a nonlinear programming problem for solving the optimal feed-forward parameters was established, from which the most excellent feed-forward form can be obtained. Results of 440T/H fluidized bed boiler show that the proposed method has satisfactory control effect. SO2concentration can fully meet environmental emissions requirements, and its fluctuation is relatively small.","PeriodicalId":114901,"journal":{"name":"Proceedings of the 10th World Congress on Intelligent Control and Automation","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on control method combined with load coordinate for dry desulfurization of slurry fluidized bed boiler\",\"authors\":\"Jiang Aipeng, Li Weiwei, Ding Qiang, Wang Jian, Jiang Zhou-shu, H. Guohui\",\"doi\":\"10.1109/WCICA.2012.6359036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is the most effective resource use practices for slurry and slime to be used as fuel for Fluidized bed boiler. The dry desulfurization of sludge Fluidized bed boiler is a large time delay system, and load disturbance of this system changes frequently. In order to achieve stable control of SO2 emission, and meet environmental requirements, a fuzzy control technology combined with the optimal feed-forward was designed. Combined with field experience, fuzzy controller was designed by fuzzy control technology, and then the integral process was added to achieve non-error track. Based on the objective to minimize disturbance impact, and in order to coordinate the desulfurization control and steam load control, a nonlinear programming problem for solving the optimal feed-forward parameters was established, from which the most excellent feed-forward form can be obtained. Results of 440T/H fluidized bed boiler show that the proposed method has satisfactory control effect. SO2concentration can fully meet environmental emissions requirements, and its fluctuation is relatively small.\",\"PeriodicalId\":114901,\"journal\":{\"name\":\"Proceedings of the 10th World Congress on Intelligent Control and Automation\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 10th World Congress on Intelligent Control and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WCICA.2012.6359036\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 10th World Congress on Intelligent Control and Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WCICA.2012.6359036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on control method combined with load coordinate for dry desulfurization of slurry fluidized bed boiler
It is the most effective resource use practices for slurry and slime to be used as fuel for Fluidized bed boiler. The dry desulfurization of sludge Fluidized bed boiler is a large time delay system, and load disturbance of this system changes frequently. In order to achieve stable control of SO2 emission, and meet environmental requirements, a fuzzy control technology combined with the optimal feed-forward was designed. Combined with field experience, fuzzy controller was designed by fuzzy control technology, and then the integral process was added to achieve non-error track. Based on the objective to minimize disturbance impact, and in order to coordinate the desulfurization control and steam load control, a nonlinear programming problem for solving the optimal feed-forward parameters was established, from which the most excellent feed-forward form can be obtained. Results of 440T/H fluidized bed boiler show that the proposed method has satisfactory control effect. SO2concentration can fully meet environmental emissions requirements, and its fluctuation is relatively small.