流动注射分析法用聚吡咯修饰电极测定乙醇燃料中的硫酸盐

M. D. S. Castilho, H. Yamanaka, M. F. D. Oliveira, M. Zanoni, N. Stradiotto
{"title":"流动注射分析法用聚吡咯修饰电极测定乙醇燃料中的硫酸盐","authors":"M. D. S. Castilho, H. Yamanaka, M. F. D. Oliveira, M. Zanoni, N. Stradiotto","doi":"10.5958/J.0976-3015.1.2.027","DOIUrl":null,"url":null,"abstract":"In this work, an electrode chemically modified with polypyrrole (PCME) was employed for determination of sulfate in ethanol fuel using a FIA system. The PCME was prepared by polymerization of pyrrole at a glassy carbon electrode by means of cyclic voltammetry technique. An analytical curve from 1.0 x 10−5 to 8.0 x 10−5 mol L−1 was obtained in flow injection system based on the PCME. An amperometric sensibility of 2.3 x 10−3 A mol−1 L and a detection limit of 2.5 x 10−6 mol L−1 were achieved. The proposed method was employed for determination of sulfate ions in commercial samples of ethanol fuel. The results were in good agreement with those obtained by the ionic chromatographic method.","PeriodicalId":107641,"journal":{"name":"Journal of Biofuels","volume":"90 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of Sulfate in Ethanol Fuel using an Electrode Chemically Modified with Polypyrrole by Flow Injection Analysis\",\"authors\":\"M. D. S. Castilho, H. Yamanaka, M. F. D. Oliveira, M. Zanoni, N. Stradiotto\",\"doi\":\"10.5958/J.0976-3015.1.2.027\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, an electrode chemically modified with polypyrrole (PCME) was employed for determination of sulfate in ethanol fuel using a FIA system. The PCME was prepared by polymerization of pyrrole at a glassy carbon electrode by means of cyclic voltammetry technique. An analytical curve from 1.0 x 10−5 to 8.0 x 10−5 mol L−1 was obtained in flow injection system based on the PCME. An amperometric sensibility of 2.3 x 10−3 A mol−1 L and a detection limit of 2.5 x 10−6 mol L−1 were achieved. The proposed method was employed for determination of sulfate ions in commercial samples of ethanol fuel. The results were in good agreement with those obtained by the ionic chromatographic method.\",\"PeriodicalId\":107641,\"journal\":{\"name\":\"Journal of Biofuels\",\"volume\":\"90 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biofuels\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5958/J.0976-3015.1.2.027\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biofuels","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5958/J.0976-3015.1.2.027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用聚吡咯(PCME)修饰电极,用FIA系统测定了乙醇燃料中的硫酸盐。采用循环伏安法在玻碳电极上聚合吡咯制备了PCME。在流动注射系统中,PCME得到了1.0 × 10−5 ~ 8.0 × 10−5 mol L−1的分析曲线。检测灵敏度为2.3 × 10−3 mol−1 L,检出限为2.5 × 10−6 mol L−1。该方法可用于工业乙醇燃料样品中硫酸盐离子的测定。结果与离子色谱法的结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of Sulfate in Ethanol Fuel using an Electrode Chemically Modified with Polypyrrole by Flow Injection Analysis
In this work, an electrode chemically modified with polypyrrole (PCME) was employed for determination of sulfate in ethanol fuel using a FIA system. The PCME was prepared by polymerization of pyrrole at a glassy carbon electrode by means of cyclic voltammetry technique. An analytical curve from 1.0 x 10−5 to 8.0 x 10−5 mol L−1 was obtained in flow injection system based on the PCME. An amperometric sensibility of 2.3 x 10−3 A mol−1 L and a detection limit of 2.5 x 10−6 mol L−1 were achieved. The proposed method was employed for determination of sulfate ions in commercial samples of ethanol fuel. The results were in good agreement with those obtained by the ionic chromatographic method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信