{"title":"确定凸极同步发电机定子-磁场绕组互感函数的简单方法","authors":"K. Ludwinek","doi":"10.1109/ISEM.2017.7993576","DOIUrl":null,"url":null,"abstract":"This paper presents a simple method for determining the stator and field winding mutual inductances. The mutual inductances are determined on the basis of experimental measurement of the induced stator phase voltages for a salient pole synchronous generator with 10 damping bars and rotor skew. A mathematical model of a salient pole synchronous generator with 10 damping bars and rotor skew in the natural reference frame is presented. During the simulation, current waveforms calculated in damping bars in a no-load steady state are presented.","PeriodicalId":286682,"journal":{"name":"2017 International Symposium on Electrical Machines (SME)","volume":"101-102 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A simple way of determining stator-to-field winding mutual inductance functions of a salient pole synchronous generator\",\"authors\":\"K. Ludwinek\",\"doi\":\"10.1109/ISEM.2017.7993576\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a simple method for determining the stator and field winding mutual inductances. The mutual inductances are determined on the basis of experimental measurement of the induced stator phase voltages for a salient pole synchronous generator with 10 damping bars and rotor skew. A mathematical model of a salient pole synchronous generator with 10 damping bars and rotor skew in the natural reference frame is presented. During the simulation, current waveforms calculated in damping bars in a no-load steady state are presented.\",\"PeriodicalId\":286682,\"journal\":{\"name\":\"2017 International Symposium on Electrical Machines (SME)\",\"volume\":\"101-102 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Symposium on Electrical Machines (SME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEM.2017.7993576\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Symposium on Electrical Machines (SME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEM.2017.7993576","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A simple way of determining stator-to-field winding mutual inductance functions of a salient pole synchronous generator
This paper presents a simple method for determining the stator and field winding mutual inductances. The mutual inductances are determined on the basis of experimental measurement of the induced stator phase voltages for a salient pole synchronous generator with 10 damping bars and rotor skew. A mathematical model of a salient pole synchronous generator with 10 damping bars and rotor skew in the natural reference frame is presented. During the simulation, current waveforms calculated in damping bars in a no-load steady state are presented.