D. Brocilo, Jen-Shih Chang, D. Ewing, H. Hirata, S. Matsumoto, P. Fanson
{"title":"直流电流体动力雾化癸烷重整","authors":"D. Brocilo, Jen-Shih Chang, D. Ewing, H. Hirata, S. Matsumoto, P. Fanson","doi":"10.1109/ICDL.2011.6015406","DOIUrl":null,"url":null,"abstract":"An experimental investigation has been conducted to study decane reforming by an electrohydrodynamic atomization system (EHDA). The EHDA had a hollow-tube electrode in a ceramic tube with a hollow-ring that acted as the ground electrode. The EHDA system was positioned in a grounded metallic chamber. Experiments were conducted for decane flow rates of 2 to 6 mL/min and applied dc voltages of 0 to 35 kV. The results showed that significant cracking of the decane could be achieved using the EHD atomization system. The amount of cracking depended on both the applied voltage and the decane flow rate.","PeriodicalId":364451,"journal":{"name":"2011 IEEE International Conference on Dielectric Liquids","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Decane reforming by a dc electrohydrodynamic atomization\",\"authors\":\"D. Brocilo, Jen-Shih Chang, D. Ewing, H. Hirata, S. Matsumoto, P. Fanson\",\"doi\":\"10.1109/ICDL.2011.6015406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An experimental investigation has been conducted to study decane reforming by an electrohydrodynamic atomization system (EHDA). The EHDA had a hollow-tube electrode in a ceramic tube with a hollow-ring that acted as the ground electrode. The EHDA system was positioned in a grounded metallic chamber. Experiments were conducted for decane flow rates of 2 to 6 mL/min and applied dc voltages of 0 to 35 kV. The results showed that significant cracking of the decane could be achieved using the EHD atomization system. The amount of cracking depended on both the applied voltage and the decane flow rate.\",\"PeriodicalId\":364451,\"journal\":{\"name\":\"2011 IEEE International Conference on Dielectric Liquids\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE International Conference on Dielectric Liquids\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICDL.2011.6015406\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Dielectric Liquids","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDL.2011.6015406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Decane reforming by a dc electrohydrodynamic atomization
An experimental investigation has been conducted to study decane reforming by an electrohydrodynamic atomization system (EHDA). The EHDA had a hollow-tube electrode in a ceramic tube with a hollow-ring that acted as the ground electrode. The EHDA system was positioned in a grounded metallic chamber. Experiments were conducted for decane flow rates of 2 to 6 mL/min and applied dc voltages of 0 to 35 kV. The results showed that significant cracking of the decane could be achieved using the EHD atomization system. The amount of cracking depended on both the applied voltage and the decane flow rate.