高频开关型变换器变压器的分析最小损耗设计

G. Callander, A. Gardiner, S. Johnson
{"title":"高频开关型变换器变压器的分析最小损耗设计","authors":"G. Callander, A. Gardiner, S. Johnson","doi":"10.1109/APEC.1995.468974","DOIUrl":null,"url":null,"abstract":"The transformer design philosophy presented is based on fundamental principles and facilitates the design of close to optimum transformers, without significant iteration. No new theoretical material is presented, but rather an analytical procedure that accords priority to minimising losses. The power transfer capacity of a transformer is constrained by its allowable operating temperature, a function of the power loss. A single total loss equation is derived consisting of core and winding components. The implicit assumptions are valid where skin depth and winding layers do not introduce significant proximity effect. A practical design example is included.<<ETX>>","PeriodicalId":335367,"journal":{"name":"Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Analytical minimal loss design of transformers for high frequency switch mode convertors\",\"authors\":\"G. Callander, A. Gardiner, S. Johnson\",\"doi\":\"10.1109/APEC.1995.468974\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The transformer design philosophy presented is based on fundamental principles and facilitates the design of close to optimum transformers, without significant iteration. No new theoretical material is presented, but rather an analytical procedure that accords priority to minimising losses. The power transfer capacity of a transformer is constrained by its allowable operating temperature, a function of the power loss. A single total loss equation is derived consisting of core and winding components. The implicit assumptions are valid where skin depth and winding layers do not introduce significant proximity effect. A practical design example is included.<<ETX>>\",\"PeriodicalId\":335367,\"journal\":{\"name\":\"Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.1995.468974\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.1995.468974","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

所提出的变压器设计理念基于基本原理,便于设计接近最优的变压器,而不需要大量的迭代。没有新的理论材料提出,而是一个分析程序,优先考虑尽量减少损失。变压器的功率传输能力受其允许工作温度的限制,这是功率损耗的函数。导出了由铁芯和绕组组成的单一总损耗方程。当蒙皮深度和缠绕层不引入显著的接近效应时,隐式假设是有效的。并给出了一个实际的设计实例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analytical minimal loss design of transformers for high frequency switch mode convertors
The transformer design philosophy presented is based on fundamental principles and facilitates the design of close to optimum transformers, without significant iteration. No new theoretical material is presented, but rather an analytical procedure that accords priority to minimising losses. The power transfer capacity of a transformer is constrained by its allowable operating temperature, a function of the power loss. A single total loss equation is derived consisting of core and winding components. The implicit assumptions are valid where skin depth and winding layers do not introduce significant proximity effect. A practical design example is included.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信