{"title":"用皮下监测装置检测心房颤动","authors":"G. Hindricks, M. Táborský, P. Wohlgemuth, G. Rieger, F. Beckers, B. Albers","doi":"10.1109/CIC.2008.4749066","DOIUrl":null,"url":null,"abstract":"The Reveal XT subcutaneous insertable cardiac monitor detects Atrial Fibrillation (AF) from the irregularity of the ventricular rhythm. This study is a first assessment of the AF detection performance using subcutaneous signals from implanted devices. Patients implanted with a Reveal XT device were monitored by a dedicated Holter system, recording the surface ECG and uplinked device data. Device detections of AF were reconstructed from the uplinked data and classified as either true positive, false positive and false negative using the surface ECG for reference. In a total of 82 Holter recordings from 60 patients, the mean AF episode detection sensitivity was 90.6% and 98.1% for AF episodes ges2 minutes and ges4 minutes, respectively. The mean episode PPV was 55.1%. False positive detections were clustered within a few patients with irregular rhythms that were not annotated as AF.","PeriodicalId":194782,"journal":{"name":"2008 Computers in Cardiology","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Atrial Fibrillation detection by a subcutaneous monitoring device\",\"authors\":\"G. Hindricks, M. Táborský, P. Wohlgemuth, G. Rieger, F. Beckers, B. Albers\",\"doi\":\"10.1109/CIC.2008.4749066\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Reveal XT subcutaneous insertable cardiac monitor detects Atrial Fibrillation (AF) from the irregularity of the ventricular rhythm. This study is a first assessment of the AF detection performance using subcutaneous signals from implanted devices. Patients implanted with a Reveal XT device were monitored by a dedicated Holter system, recording the surface ECG and uplinked device data. Device detections of AF were reconstructed from the uplinked data and classified as either true positive, false positive and false negative using the surface ECG for reference. In a total of 82 Holter recordings from 60 patients, the mean AF episode detection sensitivity was 90.6% and 98.1% for AF episodes ges2 minutes and ges4 minutes, respectively. The mean episode PPV was 55.1%. False positive detections were clustered within a few patients with irregular rhythms that were not annotated as AF.\",\"PeriodicalId\":194782,\"journal\":{\"name\":\"2008 Computers in Cardiology\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Computers in Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2008.4749066\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Computers in Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2008.4749066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

Reveal XT皮下可插入心脏监测仪从心室节律不规律中检测心房颤动(AF)。这项研究是首次评估使用植入设备的皮下信号检测AF的性能。植入Reveal XT设备的患者由专用的动态心电图系统监测,记录体表心电图和上行设备数据。根据上传的数据重建心房颤动的设备检测,并参考体表心电图将其分类为真阳性、假阳性和假阴性。在60例患者的82份霍尔特记录中,AF发作ges2分钟和ges4分钟的平均AF发作检测灵敏度分别为90.6%和98.1%。平均PPV为55.1%。假阳性检测集中在少数心律失常患者中,这些患者未被注释为房颤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Atrial Fibrillation detection by a subcutaneous monitoring device
The Reveal XT subcutaneous insertable cardiac monitor detects Atrial Fibrillation (AF) from the irregularity of the ventricular rhythm. This study is a first assessment of the AF detection performance using subcutaneous signals from implanted devices. Patients implanted with a Reveal XT device were monitored by a dedicated Holter system, recording the surface ECG and uplinked device data. Device detections of AF were reconstructed from the uplinked data and classified as either true positive, false positive and false negative using the surface ECG for reference. In a total of 82 Holter recordings from 60 patients, the mean AF episode detection sensitivity was 90.6% and 98.1% for AF episodes ges2 minutes and ges4 minutes, respectively. The mean episode PPV was 55.1%. False positive detections were clustered within a few patients with irregular rhythms that were not annotated as AF.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信