{"title":"基于小波的DFIG配电系统定向过流保护评估","authors":"M. R. Marques, M. M. Leal, F. Costa, L. S. Barros","doi":"10.1109/wcnps.2018.8604394","DOIUrl":null,"url":null,"abstract":"Currently, the wind energy conversion systems (WECS) are increasing its penetration on the electrical grid, due to the need for sustainability and alternative energy sources. Therefore, to verify if the relay-based protection systems are capable of identifying electrical faults in a distribution system with a great number of distributed generation (DG) of the doubly-fed induction generator (DFIG) type is essential. Notwithstanding, the wavelet-based directional overcurrent protection at the 30 bus bar IEEE distribution system with different percentage of DFIG-based DG's insertion on grid is analyzed. Simulated results using Matlab/Simulink are presented to verify if the protection is capable to detect backward and forward faults at this scenario. Finally, considering the overall system performance, the protection assessed is concluded being reliable.","PeriodicalId":148750,"journal":{"name":"2018 Workshop on Communication Networks and Power Systems (WCNPS)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of Wavelet-based Directional Overcurrent Protection in a Distribution System with DFIG\",\"authors\":\"M. R. Marques, M. M. Leal, F. Costa, L. S. Barros\",\"doi\":\"10.1109/wcnps.2018.8604394\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Currently, the wind energy conversion systems (WECS) are increasing its penetration on the electrical grid, due to the need for sustainability and alternative energy sources. Therefore, to verify if the relay-based protection systems are capable of identifying electrical faults in a distribution system with a great number of distributed generation (DG) of the doubly-fed induction generator (DFIG) type is essential. Notwithstanding, the wavelet-based directional overcurrent protection at the 30 bus bar IEEE distribution system with different percentage of DFIG-based DG's insertion on grid is analyzed. Simulated results using Matlab/Simulink are presented to verify if the protection is capable to detect backward and forward faults at this scenario. Finally, considering the overall system performance, the protection assessed is concluded being reliable.\",\"PeriodicalId\":148750,\"journal\":{\"name\":\"2018 Workshop on Communication Networks and Power Systems (WCNPS)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Workshop on Communication Networks and Power Systems (WCNPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/wcnps.2018.8604394\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Workshop on Communication Networks and Power Systems (WCNPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/wcnps.2018.8604394","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Assessment of Wavelet-based Directional Overcurrent Protection in a Distribution System with DFIG
Currently, the wind energy conversion systems (WECS) are increasing its penetration on the electrical grid, due to the need for sustainability and alternative energy sources. Therefore, to verify if the relay-based protection systems are capable of identifying electrical faults in a distribution system with a great number of distributed generation (DG) of the doubly-fed induction generator (DFIG) type is essential. Notwithstanding, the wavelet-based directional overcurrent protection at the 30 bus bar IEEE distribution system with different percentage of DFIG-based DG's insertion on grid is analyzed. Simulated results using Matlab/Simulink are presented to verify if the protection is capable to detect backward and forward faults at this scenario. Finally, considering the overall system performance, the protection assessed is concluded being reliable.