S. Rahim, T. Rahman, I. Musirin, M. H. Hussain, M. Sulaiman, O. Aliman, Z. M. Isa
{"title":"在配电系统中实施DG以实现损耗最小化和电压分布","authors":"S. Rahim, T. Rahman, I. Musirin, M. H. Hussain, M. Sulaiman, O. Aliman, Z. M. Isa","doi":"10.1109/PEOCO.2010.5559251","DOIUrl":null,"url":null,"abstract":"This paper presents the effects of DG on the performance of an existing distribution network in terms of voltage stability, loss minimization and voltage profile. In this study, a new program was developed based on Artificial Immune System optimization technique in order to determine the optimal size of distributed generator. Various loading conditions were tested in order to evaluate the effectiveness of the proposed technique in determining the optimal size of the distributed generator. The suitable location of distributed generator is identified based on the results from voltage stability index. The proposed technique was tested on IEEE Reliability Test systems namely the IEEE 69-bus and the program was developed using the MATLAB programming software.","PeriodicalId":379868,"journal":{"name":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Implementation of DG for loss minimization and voltage profile in distribution system\",\"authors\":\"S. Rahim, T. Rahman, I. Musirin, M. H. Hussain, M. Sulaiman, O. Aliman, Z. M. Isa\",\"doi\":\"10.1109/PEOCO.2010.5559251\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the effects of DG on the performance of an existing distribution network in terms of voltage stability, loss minimization and voltage profile. In this study, a new program was developed based on Artificial Immune System optimization technique in order to determine the optimal size of distributed generator. Various loading conditions were tested in order to evaluate the effectiveness of the proposed technique in determining the optimal size of the distributed generator. The suitable location of distributed generator is identified based on the results from voltage stability index. The proposed technique was tested on IEEE Reliability Test systems namely the IEEE 69-bus and the program was developed using the MATLAB programming software.\",\"PeriodicalId\":379868,\"journal\":{\"name\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEOCO.2010.5559251\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEOCO.2010.5559251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Implementation of DG for loss minimization and voltage profile in distribution system
This paper presents the effects of DG on the performance of an existing distribution network in terms of voltage stability, loss minimization and voltage profile. In this study, a new program was developed based on Artificial Immune System optimization technique in order to determine the optimal size of distributed generator. Various loading conditions were tested in order to evaluate the effectiveness of the proposed technique in determining the optimal size of the distributed generator. The suitable location of distributed generator is identified based on the results from voltage stability index. The proposed technique was tested on IEEE Reliability Test systems namely the IEEE 69-bus and the program was developed using the MATLAB programming software.