采用自适应卡尔曼滤波方法,以胸部按压频率为参考信号,从VF信号中去除心肺复苏术伪影

S. de Gauna, J. Ruiz, U. Irusta, E. Aramendi, A. Lazkano, J. Gutierrez
{"title":"采用自适应卡尔曼滤波方法,以胸部按压频率为参考信号,从VF信号中去除心肺复苏术伪影","authors":"S. de Gauna, J. Ruiz, U. Irusta, E. Aramendi, A. Lazkano, J. Gutierrez","doi":"10.1109/CIC.2005.1588064","DOIUrl":null,"url":null,"abstract":"Chest compressions during Cardiopulmonary Resuscitation (CPR) generate important artefacts which impede the correct analysis of the ECG signal by an automated external defibrillator (AED). The suppression of the CPR artefact is thus necessary during resuscitation. The filtering technique proposed in the present paper is based on a Kalman adaptive scheme where the CPR artefact model follows the instantaneous frequency of the chest compressions, while the VF signal is modeled as a sum of two sinusoidal signals. The good results obtained for the increase of the signal to noise ratio and the excellent sensitivity scores provided by a commercial AED on the cleaned VF signals certifies the value of the method","PeriodicalId":239491,"journal":{"name":"Computers in Cardiology, 2005","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"CPR artefact removal from VF signals by means of an adaptive kalman filter using the chest compression frequency as reference signal\",\"authors\":\"S. de Gauna, J. Ruiz, U. Irusta, E. Aramendi, A. Lazkano, J. Gutierrez\",\"doi\":\"10.1109/CIC.2005.1588064\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Chest compressions during Cardiopulmonary Resuscitation (CPR) generate important artefacts which impede the correct analysis of the ECG signal by an automated external defibrillator (AED). The suppression of the CPR artefact is thus necessary during resuscitation. The filtering technique proposed in the present paper is based on a Kalman adaptive scheme where the CPR artefact model follows the instantaneous frequency of the chest compressions, while the VF signal is modeled as a sum of two sinusoidal signals. The good results obtained for the increase of the signal to noise ratio and the excellent sensitivity scores provided by a commercial AED on the cleaned VF signals certifies the value of the method\",\"PeriodicalId\":239491,\"journal\":{\"name\":\"Computers in Cardiology, 2005\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computers in Cardiology, 2005\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2005.1588064\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in Cardiology, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2005.1588064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

心肺复苏(CPR)过程中的胸部按压会产生重要的伪影,妨碍自动体外除颤器(AED)正确分析心电信号。因此,在复苏过程中抑制CPR伪影是必要的。本文提出的滤波技术基于卡尔曼自适应方案,其中CPR伪影模型遵循胸外按压的瞬时频率,而VF信号被建模为两个正弦信号的和。在提高信噪比方面取得了良好的效果,商用AED对清洗后的VF信号给出了优异的灵敏度分数,证明了该方法的价值
本文章由计算机程序翻译,如有差异,请以英文原文为准。
CPR artefact removal from VF signals by means of an adaptive kalman filter using the chest compression frequency as reference signal
Chest compressions during Cardiopulmonary Resuscitation (CPR) generate important artefacts which impede the correct analysis of the ECG signal by an automated external defibrillator (AED). The suppression of the CPR artefact is thus necessary during resuscitation. The filtering technique proposed in the present paper is based on a Kalman adaptive scheme where the CPR artefact model follows the instantaneous frequency of the chest compressions, while the VF signal is modeled as a sum of two sinusoidal signals. The good results obtained for the increase of the signal to noise ratio and the excellent sensitivity scores provided by a commercial AED on the cleaned VF signals certifies the value of the method
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信