S. de Gauna, J. Ruiz, U. Irusta, E. Aramendi, A. Lazkano, J. Gutierrez
{"title":"采用自适应卡尔曼滤波方法,以胸部按压频率为参考信号,从VF信号中去除心肺复苏术伪影","authors":"S. de Gauna, J. Ruiz, U. Irusta, E. Aramendi, A. Lazkano, J. Gutierrez","doi":"10.1109/CIC.2005.1588064","DOIUrl":null,"url":null,"abstract":"Chest compressions during Cardiopulmonary Resuscitation (CPR) generate important artefacts which impede the correct analysis of the ECG signal by an automated external defibrillator (AED). The suppression of the CPR artefact is thus necessary during resuscitation. The filtering technique proposed in the present paper is based on a Kalman adaptive scheme where the CPR artefact model follows the instantaneous frequency of the chest compressions, while the VF signal is modeled as a sum of two sinusoidal signals. The good results obtained for the increase of the signal to noise ratio and the excellent sensitivity scores provided by a commercial AED on the cleaned VF signals certifies the value of the method","PeriodicalId":239491,"journal":{"name":"Computers in Cardiology, 2005","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"CPR artefact removal from VF signals by means of an adaptive kalman filter using the chest compression frequency as reference signal\",\"authors\":\"S. de Gauna, J. Ruiz, U. Irusta, E. Aramendi, A. Lazkano, J. Gutierrez\",\"doi\":\"10.1109/CIC.2005.1588064\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Chest compressions during Cardiopulmonary Resuscitation (CPR) generate important artefacts which impede the correct analysis of the ECG signal by an automated external defibrillator (AED). The suppression of the CPR artefact is thus necessary during resuscitation. The filtering technique proposed in the present paper is based on a Kalman adaptive scheme where the CPR artefact model follows the instantaneous frequency of the chest compressions, while the VF signal is modeled as a sum of two sinusoidal signals. The good results obtained for the increase of the signal to noise ratio and the excellent sensitivity scores provided by a commercial AED on the cleaned VF signals certifies the value of the method\",\"PeriodicalId\":239491,\"journal\":{\"name\":\"Computers in Cardiology, 2005\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computers in Cardiology, 2005\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2005.1588064\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in Cardiology, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2005.1588064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
CPR artefact removal from VF signals by means of an adaptive kalman filter using the chest compression frequency as reference signal
Chest compressions during Cardiopulmonary Resuscitation (CPR) generate important artefacts which impede the correct analysis of the ECG signal by an automated external defibrillator (AED). The suppression of the CPR artefact is thus necessary during resuscitation. The filtering technique proposed in the present paper is based on a Kalman adaptive scheme where the CPR artefact model follows the instantaneous frequency of the chest compressions, while the VF signal is modeled as a sum of two sinusoidal signals. The good results obtained for the increase of the signal to noise ratio and the excellent sensitivity scores provided by a commercial AED on the cleaned VF signals certifies the value of the method