{"title":"用数字全息断层摄影法测量传热传质","authors":"R. Dolecek, P. Psota, V. Ledl, T. Vít","doi":"10.1117/12.2257476","DOIUrl":null,"url":null,"abstract":"A digital holographic interferometry (DHI) for 3D measurement of temperature distributions in moving fluid is presented in this paper. The measurement uses digital holographic setup for measurement of a flow of fluid propagated through an orifice and tomographic approach for 3D reconstruction of the flow. The periodic character of the flow and synchronization between the digital camera and external trigger driving the phenomenon allows us to measure phenomena with much higher frequency when compared to frame rate of the digital camera. Furthermore one can capture a large number of the flow projections from different viewing directions which are later used for 3D tomographic reconstruction of the whole temperature field of the flow. The measurement results are verified and compared with hot wire method (CTA) in the paper.","PeriodicalId":112965,"journal":{"name":"Optical Angular Momentum","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Heat and mass transfer measurement using method of digital holographic tomography\",\"authors\":\"R. Dolecek, P. Psota, V. Ledl, T. Vít\",\"doi\":\"10.1117/12.2257476\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A digital holographic interferometry (DHI) for 3D measurement of temperature distributions in moving fluid is presented in this paper. The measurement uses digital holographic setup for measurement of a flow of fluid propagated through an orifice and tomographic approach for 3D reconstruction of the flow. The periodic character of the flow and synchronization between the digital camera and external trigger driving the phenomenon allows us to measure phenomena with much higher frequency when compared to frame rate of the digital camera. Furthermore one can capture a large number of the flow projections from different viewing directions which are later used for 3D tomographic reconstruction of the whole temperature field of the flow. The measurement results are verified and compared with hot wire method (CTA) in the paper.\",\"PeriodicalId\":112965,\"journal\":{\"name\":\"Optical Angular Momentum\",\"volume\":\"54 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optical Angular Momentum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2257476\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optical Angular Momentum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2257476","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种用于三维测量流动流体温度分布的数字全息干涉法。测量使用数字全息装置来测量通过孔板传播的流体流动,并使用层析方法对流动进行三维重建。数码相机与驱动该现象的外部触发器之间的流动和同步的周期性特性使我们能够以比数码相机的帧速率高得多的频率测量该现象。此外,人们可以从不同的观察方向捕获大量的流动投影,这些投影后来被用于整个流动温度场的三维层析重建。对测量结果进行了验证,并与热丝法(CTA)进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Heat and mass transfer measurement using method of digital holographic tomography
A digital holographic interferometry (DHI) for 3D measurement of temperature distributions in moving fluid is presented in this paper. The measurement uses digital holographic setup for measurement of a flow of fluid propagated through an orifice and tomographic approach for 3D reconstruction of the flow. The periodic character of the flow and synchronization between the digital camera and external trigger driving the phenomenon allows us to measure phenomena with much higher frequency when compared to frame rate of the digital camera. Furthermore one can capture a large number of the flow projections from different viewing directions which are later used for 3D tomographic reconstruction of the whole temperature field of the flow. The measurement results are verified and compared with hot wire method (CTA) in the paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信