微传感器在细长医用针头上的首次实验

A. Bonvilain, Mathilde Gangneron
{"title":"微传感器在细长医用针头上的首次实验","authors":"A. Bonvilain, Mathilde Gangneron","doi":"10.1109/DTIP.2014.7056636","DOIUrl":null,"url":null,"abstract":"Further to the first fabrication of strain microgauges on cylindrical metal substrates [1], that we cannot experiment because of problems of wire bonding, we have reviewed the bonding process. These microgauges enable the real-time measurement of the medical needle strain distribution from which its deflection status can be deduced. So this paper deals with the new bonding process of the microgauges and the detailed experimentations. These experimentations consist in constrain the needle and verify that we can measure the strain. They allow also the calculations and the comparison of the theoretical and experimental gauge factor. Finally we discuss about the improvement of the prototype in terms of optimization of the process. And some material questions must find solution.","PeriodicalId":268119,"journal":{"name":"2014 Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS (DTIP)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"First experimentations of microsensors microfabricated on a long and thin medical needle\",\"authors\":\"A. Bonvilain, Mathilde Gangneron\",\"doi\":\"10.1109/DTIP.2014.7056636\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Further to the first fabrication of strain microgauges on cylindrical metal substrates [1], that we cannot experiment because of problems of wire bonding, we have reviewed the bonding process. These microgauges enable the real-time measurement of the medical needle strain distribution from which its deflection status can be deduced. So this paper deals with the new bonding process of the microgauges and the detailed experimentations. These experimentations consist in constrain the needle and verify that we can measure the strain. They allow also the calculations and the comparison of the theoretical and experimental gauge factor. Finally we discuss about the improvement of the prototype in terms of optimization of the process. And some material questions must find solution.\",\"PeriodicalId\":268119,\"journal\":{\"name\":\"2014 Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS (DTIP)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS (DTIP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DTIP.2014.7056636\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS (DTIP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DTIP.2014.7056636","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在圆柱形金属基板上首次制造应变微计[1]后,由于金属丝粘接问题,我们无法进行实验,我们回顾了粘接过程。这些微计能够实时测量医用针头的应变分布,从而可以推断其挠曲状态。为此,本文对微规的新型粘接工艺进行了详细的实验研究。这些实验包括约束针,并验证我们可以测量应变。它们还允许计算和比较理论和实验测量因子。最后从工艺优化的角度对样机的改进进行了讨论。一些实质性的问题必须找到解决办法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
First experimentations of microsensors microfabricated on a long and thin medical needle
Further to the first fabrication of strain microgauges on cylindrical metal substrates [1], that we cannot experiment because of problems of wire bonding, we have reviewed the bonding process. These microgauges enable the real-time measurement of the medical needle strain distribution from which its deflection status can be deduced. So this paper deals with the new bonding process of the microgauges and the detailed experimentations. These experimentations consist in constrain the needle and verify that we can measure the strain. They allow also the calculations and the comparison of the theoretical and experimental gauge factor. Finally we discuss about the improvement of the prototype in terms of optimization of the process. And some material questions must find solution.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信