Fluke 57XX产品校准测试点选择的更新评估

J. Gust, S. Haynes, Billie S. Britz, Randy Lemon, Neil Faulkner, Greg Tarolli
{"title":"Fluke 57XX产品校准测试点选择的更新评估","authors":"J. Gust, S. Haynes, Billie S. Britz, Randy Lemon, Neil Faulkner, Greg Tarolli","doi":"10.51843/wsproceedings.2013.30","DOIUrl":null,"url":null,"abstract":"The first Fluke 5700 series calibrator was manufactured in the late 1980’s. The metrology and associated test point selection for calibrating the product was rigorous by any standards, then or now. However, the calibration procedure that has been in place essentially since its initial release pre-dates significant advances in hardware, such as the Fluke Calibration 792A and 5790A, as well as ISO 17025, and the popularization of voluntary calibration laboratory accreditation. Fluke Calibration has re-visited the selection of test points in the calibration procedure to ensure that the result of any 5700 series calibrator would clearly demonstrate that all specifications have been verified, and that traceability for all functions is ensured. This was accomplished by an event that brought together representatives from Design Engineering, Test Engineering, Service Engineering, Service Metrology and Corporate Metrology. The group evaluated each specification, considered the internal architecture of the product, and reviewed and improved upon the test points. This paper presents the test points for the 5700 series calibrators and the technical information as to why they were chosen.","PeriodicalId":445779,"journal":{"name":"NCSL International Workshop & Symposium Conference Proceedings 2013","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Updated Evaluation of Calibration Test Point Selection for Fluke 57XX products\",\"authors\":\"J. Gust, S. Haynes, Billie S. Britz, Randy Lemon, Neil Faulkner, Greg Tarolli\",\"doi\":\"10.51843/wsproceedings.2013.30\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The first Fluke 5700 series calibrator was manufactured in the late 1980’s. The metrology and associated test point selection for calibrating the product was rigorous by any standards, then or now. However, the calibration procedure that has been in place essentially since its initial release pre-dates significant advances in hardware, such as the Fluke Calibration 792A and 5790A, as well as ISO 17025, and the popularization of voluntary calibration laboratory accreditation. Fluke Calibration has re-visited the selection of test points in the calibration procedure to ensure that the result of any 5700 series calibrator would clearly demonstrate that all specifications have been verified, and that traceability for all functions is ensured. This was accomplished by an event that brought together representatives from Design Engineering, Test Engineering, Service Engineering, Service Metrology and Corporate Metrology. The group evaluated each specification, considered the internal architecture of the product, and reviewed and improved upon the test points. This paper presents the test points for the 5700 series calibrators and the technical information as to why they were chosen.\",\"PeriodicalId\":445779,\"journal\":{\"name\":\"NCSL International Workshop & Symposium Conference Proceedings 2013\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"NCSL International Workshop & Symposium Conference Proceedings 2013\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.51843/wsproceedings.2013.30\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"NCSL International Workshop & Symposium Conference Proceedings 2013","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51843/wsproceedings.2013.30","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

第一个福禄克5700系列校准器是在20世纪80年代后期制造的。计量和相关的测试点选择校准的产品是严格的任何标准,当时或现在。然而,自最初发布以来,校准程序基本上已经到位,早于硬件方面的重大进步,例如Fluke校准792A和5790A,以及ISO 17025,以及自愿校准实验室认可的普及。Fluke校准重新检查了校准程序中测试点的选择,以确保任何5700系列校准器的结果都清楚地表明所有规格都已经过验证,并确保所有功能的可追溯性。这次会议汇集了来自设计工程、测试工程、服务工程、服务计量和企业计量的代表。小组评估每个规范,考虑产品的内部架构,并对测试点进行审查和改进。本文介绍了5700系列校准器的测试点和选择它们的技术信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Updated Evaluation of Calibration Test Point Selection for Fluke 57XX products
The first Fluke 5700 series calibrator was manufactured in the late 1980’s. The metrology and associated test point selection for calibrating the product was rigorous by any standards, then or now. However, the calibration procedure that has been in place essentially since its initial release pre-dates significant advances in hardware, such as the Fluke Calibration 792A and 5790A, as well as ISO 17025, and the popularization of voluntary calibration laboratory accreditation. Fluke Calibration has re-visited the selection of test points in the calibration procedure to ensure that the result of any 5700 series calibrator would clearly demonstrate that all specifications have been verified, and that traceability for all functions is ensured. This was accomplished by an event that brought together representatives from Design Engineering, Test Engineering, Service Engineering, Service Metrology and Corporate Metrology. The group evaluated each specification, considered the internal architecture of the product, and reviewed and improved upon the test points. This paper presents the test points for the 5700 series calibrators and the technical information as to why they were chosen.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信