电流编程DC-DC稳压器的建模、分析和测量

N. Backman, Sifu Elektronik
{"title":"电流编程DC-DC稳压器的建模、分析和测量","authors":"N. Backman, Sifu Elektronik","doi":"10.1109/INTLEC.1987.4794597","DOIUrl":null,"url":null,"abstract":"A buck-type converter is modeled for continuos conduction mode, simulated, analysed and measured with emphasis on loop gain to be able to design for stability. As a result of this \"Structured Analog Design\" process, a new SPICE2 model for current-mode programming plus a useful formula for control voltage to output voltage transfer function has been derived. The theoretical background is based on Dr. R. D. Middlebrooks papers on the subject, (2,3). In a case study, both prediction and measurement show a second pole, in loop gain, at a surprisingly low frequency. This implies that the current-mode control, although it seems to be the best method for regulation, must be properly understood for avoiding oscillating units.","PeriodicalId":129305,"journal":{"name":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1987-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Spice-Modelling, Analysis and Measurement of a Current Programmed DC-DC Regulator\",\"authors\":\"N. Backman, Sifu Elektronik\",\"doi\":\"10.1109/INTLEC.1987.4794597\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A buck-type converter is modeled for continuos conduction mode, simulated, analysed and measured with emphasis on loop gain to be able to design for stability. As a result of this \\\"Structured Analog Design\\\" process, a new SPICE2 model for current-mode programming plus a useful formula for control voltage to output voltage transfer function has been derived. The theoretical background is based on Dr. R. D. Middlebrooks papers on the subject, (2,3). In a case study, both prediction and measurement show a second pole, in loop gain, at a surprisingly low frequency. This implies that the current-mode control, although it seems to be the best method for regulation, must be properly understood for avoiding oscillating units.\",\"PeriodicalId\":129305,\"journal\":{\"name\":\"INTELEC '87 - The Ninth International Telecommunications Energy Conference\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1987-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"INTELEC '87 - The Ninth International Telecommunications Energy Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.1987.4794597\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"INTELEC '87 - The Ninth International Telecommunications Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1987.4794597","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

针对连续导通模式,建立了buck型变换器模型,并对其进行了仿真、分析和测量,重点对回路增益进行了分析和测量,以便进行稳定性设计。由于这种“结构化模拟设计”的过程,一个新的SPICE2模型的电流模式编程加上一个有用的公式控制电压输出电压传递函数已被导出。理论背景是基于Dr. R. D. Middlebrooks关于这个主题的论文,(2,3)。在一个案例研究中,预测和测量都显示了第二极,环路增益,在惊人的低频率。这意味着,虽然电流模式控制似乎是最好的调节方法,但必须正确理解以避免振荡单元。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Spice-Modelling, Analysis and Measurement of a Current Programmed DC-DC Regulator
A buck-type converter is modeled for continuos conduction mode, simulated, analysed and measured with emphasis on loop gain to be able to design for stability. As a result of this "Structured Analog Design" process, a new SPICE2 model for current-mode programming plus a useful formula for control voltage to output voltage transfer function has been derived. The theoretical background is based on Dr. R. D. Middlebrooks papers on the subject, (2,3). In a case study, both prediction and measurement show a second pole, in loop gain, at a surprisingly low frequency. This implies that the current-mode control, although it seems to be the best method for regulation, must be properly understood for avoiding oscillating units.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信