{"title":"mosfet的加速老化试验及寿命预测","authors":"Jacob Maxa, M. Nowottnick","doi":"10.23919/empc53418.2021.9584958","DOIUrl":null,"url":null,"abstract":"An active power cycling test-bed for a power MOSFET is presented in this publication. This setup is used to create temperature dependent load cycles of 24 parallel devices. After a passive calibration step the drain-to-source voltage is used to estimate the junction temperature. The devices are then heated until a predefined value is reached. The setup is power cycled until at least 20 channels failed and then analysed using metallographic cross-sections. Furthermore, this setup records the thermal impedance of each channel over time. With these data it is possible to detect and predict a solder fatigue (crack, void) during operation. Finally after all load cycles the results were evaluated by Weibull plots and a lifetime estimation for other temperatures is given in the way of a stress-life curve. The results suggest a comparable lifetime compared to ceramic-based components, if the substrate does not have an influence as a source of faults.","PeriodicalId":348887,"journal":{"name":"2021 23rd European Microelectronics and Packaging Conference & Exhibition (EMPC)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accelerated Ageing Test and Lifetime Prediction of MOSFETs\",\"authors\":\"Jacob Maxa, M. Nowottnick\",\"doi\":\"10.23919/empc53418.2021.9584958\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An active power cycling test-bed for a power MOSFET is presented in this publication. This setup is used to create temperature dependent load cycles of 24 parallel devices. After a passive calibration step the drain-to-source voltage is used to estimate the junction temperature. The devices are then heated until a predefined value is reached. The setup is power cycled until at least 20 channels failed and then analysed using metallographic cross-sections. Furthermore, this setup records the thermal impedance of each channel over time. With these data it is possible to detect and predict a solder fatigue (crack, void) during operation. Finally after all load cycles the results were evaluated by Weibull plots and a lifetime estimation for other temperatures is given in the way of a stress-life curve. The results suggest a comparable lifetime compared to ceramic-based components, if the substrate does not have an influence as a source of faults.\",\"PeriodicalId\":348887,\"journal\":{\"name\":\"2021 23rd European Microelectronics and Packaging Conference & Exhibition (EMPC)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 23rd European Microelectronics and Packaging Conference & Exhibition (EMPC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/empc53418.2021.9584958\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 23rd European Microelectronics and Packaging Conference & Exhibition (EMPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/empc53418.2021.9584958","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Accelerated Ageing Test and Lifetime Prediction of MOSFETs
An active power cycling test-bed for a power MOSFET is presented in this publication. This setup is used to create temperature dependent load cycles of 24 parallel devices. After a passive calibration step the drain-to-source voltage is used to estimate the junction temperature. The devices are then heated until a predefined value is reached. The setup is power cycled until at least 20 channels failed and then analysed using metallographic cross-sections. Furthermore, this setup records the thermal impedance of each channel over time. With these data it is possible to detect and predict a solder fatigue (crack, void) during operation. Finally after all load cycles the results were evaluated by Weibull plots and a lifetime estimation for other temperatures is given in the way of a stress-life curve. The results suggest a comparable lifetime compared to ceramic-based components, if the substrate does not have an influence as a source of faults.